Link Clamps Specifications
Double Acting Excellent alternative to swing clamps when swing space is limited. Available in three sizes: 1, 1-1/2, and 2-1/8 inch bore. Top Flange body mount. Left, forward, or right lever position from the same body. Link clamps clear large obstructions better than other types of clamps. Manifold mounted or standard plumbed using standard NPT fittings. Levers sold separately (see page C-4).
C-2
ILSP16601 REV A
Specifications
Model Number FORWARD P1-6621-10 P1-6621-50 P1-6622-10
Lever Position RIGHT
P1-6621-11 P1-6621-51 P1-6622-11 P1-6621-12 P1-6621-52 P1-6622-12
LEFT
Bore Diameter (in.)
1.00
1.50 .125
2.125
Vertical Clamping Stroke * Standard Lever Length ** Effective Piston Area (sq. in.) Extend
.09
.125
1.875
2.625
3.094
.785 .479 1.15
1.767 1.325
3.546 2.761
Retract
Air Consumption (cu. in.) ***
3.48
8.63
Operating Pressure Range: 30-250 psi Fluid: Clean Dry Air Lubrication: Not Required * Equal to ±3 O with standard lever.
Lever can be easily positioned in any one of the three directions in relation to the ports.
** Use of extended length arms will result in a reduction of clamp capacity. See graphs of lever output curves for clamping force of various arm lengths. The clamping force is adjustable by varying the pneumatic system pressure. To insure maximum service life and trouble-free operation, these devices should be positioned in no less than 1/2 second. These recommendations apply when using the standard arm. When using the optional long arm or your custom arm, please restrict the flow rates to position the arm in no less than 1 second. *** Per complete cycle.
Operating temperature limits are 32-150° F
LINK CLAMPS SHOWN WITH STANDARD LENGTH LEVERS Levers sold separately (page C-4)
800-992-0236 © Vektek January 2022