Vektek Metric Hydraulic Clamping Catalog

Compact Clamps

Compact Clamps with Pneumatic Sensing Information

Patent Pending

Double Acting Compact Clamp with Pneumatic Sensing Engineered to use air pressure to provide clamp position feedback to machine systems. Once clamped, air pressure will build up to the set point.  All of the same features you love about the compact clamp, with the bonus of pneumatic clamp confirmation!  Pneumatic Sensing will show a change in air pressure if the clamp overtravels or is not in clamped position.  Use with Vektek’s Air Sensing Control Kit 45-0824-00.

BTM M1 M2 TOP

SEE NEXT PAGE FOR TOP&BTM STROKE DIMS AIR PRESSURE BUILDS BETWEEN POINT M1&M2

E-2

ILMV175201 REV A

Oil Capacity (cm 3 )*** POINT M1

Patent Pending

POINT M2

Effective Piston Area (cm 2 ) 103 KPa

Sensing Range (mm)

Vertical Clamp Stroke (mm)**

Total Stroke (Flipback + Vertical) (mm)

Maximum Flow Rate (L/min) ***

Clamp Capacity (kN)*

Sensing Stroke (mm)

Model No.

Bottom (M1)

Top (M2)

Retracted Extended Retracted

14KPa

Double Acting (D/A)

Cylinders, actuated hydraulically both directions.

41-7521-70-PP

750

.19 .21 .29 .30

.09 .11 .14 .20

.59 .76 .95

.223 .293 .482 .789

.196 .131 .370 .221 .747 .456 1.352 .859

16 27

.35 .44 .37 .48 .47 .61 .50 .70

BTM M1 M2 TOP

55 POSSIBLE OVERTRAVEL (AIR FLOWS) 104

CLAMP (NO AIR FLOWS)

41-7522-00-PP 1,000 41-7522-50-PP 1,750 41-7523-20-PP 2,750

UNCLAMP (AIR FLOWS)

1.10

Warning! Never allow arm to contact workpiece or fixture during actuation. * Cylinder capacities are listed at 350 bar maximum operating pressure, with a short arm installed. Minimum operating pressure of 35 bar is required for double acting applications. The clamping force is adjustable by varying the hydraulic system pressure. To determine the approximate clamping force for your application, see ISM1776. ** To allow for piece part height variations, it is recommended that the vertical travel be set at about 50% of the vertical stroke. *** To ensure maximum service life and trouble-free operation, restrict fluid flow to the above flow ratings. If you are unable to measure flow rates, adjust flow so that the clamping action occurs in no less than half a second. If using extended arm either quarter the above flow rates, or time clamping action to be no less than two seconds. ILMV175201 REV A SEE NEXT PAGE FOR TOP&BTM STROKE DIMS AIR PRESSURE BUILDS BETWEEN POINT M1&M2

POINT M1

POINT M2

103 KPa

14KPa

POSSIBLE OVERTRAVEL (AIR FLOWS)

CLAMP (NO AIR FLOWS)

UNCLAMP (AIR FLOWS)

www.vektek.com

Outside US+1-913-365-1045

© Vektek December 2021