Special Use Clamps
Pull-Down Clamp Manifold Mounted Specifications and Dimensions
ILMV153109 REV F
Single Acting Pull-Down Clamp, Spring Return, Manifold Mounted
G .5
Y BY X DP
Used whenever edge face clamping is desired. Generates straight clamping motion and force along with pull-down clamping force to hold and pull down parts. Pull-down force is approximately 1/3 of the respective clamping force. Standard version with serrated and hardened jaw, complete with mounting bolts (ISO). Optional jaws are available in this section. Oil supply through threaded ports or manifold.
E-11
2x H
CLAMP PORT MANIFOLD MOUNT*
3x L
C
2x M
S
4x THREAD N P
Q
J
2x K
A
D STROKE
2x R
Jaws and pistons are connected by a joint that avoids the introduction of a bending movement to the piston and extends clamp life. Body of burnished tempered steel with case-hardened ground pistons for long life. Fastened with two mounting bolts from above and four bolts from the bottom to insure maximum hold within operating limits.
B
F
ILMV153104 REV H
E
Specifications
Force at 400 bar (40 MPa) (kN)
Stroke D (mm)
Oil Volume (cm 3 )
Mounting Screws 2 pieces
Torque Maximum (Nm)
Spring Force Minimum (N)
Model No.
Weight (g)
Single Acting (S/A) Cylinders, actuated hydraulically 1 direction, spring returned.
41-5311-05 41-5311-20 41-5311-32 41-5311-50
4.5
5 8
0.57
M8 x 45 M12 x 80 M16 x 100 M20 x 120
21 72
60
670
20 32 50
4 8
160 210 340
2500 4700 8800
10 12
180 350
15
Dimensions
Model No.
A BCDEFGHJKLMNPQ R S X Y Single Acting (S/A) Cylinders, actuated hydraulically 1 direction, spring returned.
41-5311-05 100 30 30 5 2 3 39 8.5 53 59 11 22 M5 6 13 G 1/8 M3 N/A N/A 41-5311-20 135 50 50 8 3 14 58 12.5 67 74 18 36 M8 12 14 G 1/4 M5 6 28 41-5311-32 149.5 65 65 10 3 17 63.5 16.5 72 83 23.5 47 M10 16 17.5 G 1/4 M5 6 32 41-5311-50 180 80 80 12 3 19 71 20.5 93 104 30 60 M12 25 21 G 1/4 M5 N/A N/A
All dimensions are in mm.
NOTE: Do not overstress mounting bolts.
Observe maximum permissible torque.
Vertical travel should be restricted so that stroke "E" cannot be exceeded. *For manifold mounting, remove the (S) screw and sealing washer and install the included o-ring.
For proper sealing, the mating surface must be flat within 0.08 mm with a maximum surface roughness of 1.6 µm R a
Maximum operating pressure 400 bar (40 MPa)