Vektek Metric Hydraulic Clamping Catalog

Palletized Fixture Accessories

Automatic Shutoff Valve Decoupler Block and Two-Handed Operating Handle

Automatic Shutoff Valve Decouplers for Single and Double Acting Systems

 Decouplers are a convenient, self-contained package that includes quick connect couplings, accumulator, filters, over pressure relief valve and a pilot operated check valve.  External ports and manifold mounting connections (bottom and rear) are G 1/4 female.  Robust pilot operated check valve with 1:5 pilot to check pressure extends proven long-term reliability.  Check valve has added protection from the internal 25 micron filter.  Single acting pallet circuits require 2 hoses to the Operating Handle for pressure release.

In-Line Filter Cartridge

Filter Plate (For Manifold Mount) 47-0842-05 (Bottom A5 & B5) or 47-0842-06 (Rear A4 & B4)

Pressure Range Bar (MPa)

Accumulator Capacity (cm 3 )

Model No.

45-6007-03 NO ACCUMULATOR 350 BAR MAX

45-6007-30 30-100 (3-10 MPa) 45-6007-31 70-250 (7-25 MPa) 45-6007-32 140-350 (14-35 MPa)

62 59 52

47-0048-81

For use with Operating Handle Model No. 45-6005-04.

57.5 117.3

31.5

PLUG "B" PORT FOR S/A SYSTEMS

B4 A4

B4

A4

A3

For single hose systems see the Manual Shutoff Valve Decoupler.

A2 A5

B2 B5 B3

28.6

G1/4 PORT ADAPTER. USE IN END PORT IF REQUIRED. (SHIPPED LOOSE).

G1/4 MANIFOLD MOUNT

 Additional filtration available for the B return port through the use of manifold mount and in-line filtration.

B1 C1 A1

MINIMUM OF 20% CLAMP PRESSURE MUST BE APPLIED TO UNCLAMP

"B1" QUICK CONNECTOR UNCLAMP

67.1

22

"A1" QUICK CONNECTOR CLAMP

DRILLED FOR M6 SHCS (4X)

54

B5

A5

31.8

4.8

108 57.5

31.5

57.2

G1/4 MANIFOLD MOUNT

4.8

K-6

DRILLED FOR M6 SHCS (3X)

139.5

119.3

Two-Handed Operating Handle n Maximum working pressure - 350 bar (35 MPa)  Provides a fast, positive connection to the decoupler. connected to tank) directional control valve for operation of single or double acting systems. One automatic shutoff valve decoupler can be used to operate only one double acting or one single acting circuit. For operation of a single acting circuit, plug the decoupler outlet port “B” (as shown in the schematic). n Ergonomic design reduces operator fatigue. n The Two-Handed Handle may be used with the optional Handle Docking Module to assure that the hoses are disconnected from the pallet before it is shuttled into the machine. n SAFETY: See Docking Station -(End of Section K) NOTE: These automatic shutoff valve decouplers and operating handle must be used with a suitable pump which includes a 4 port/3 position, P-blocked center (“A” & “B”

19 (8X)

32.9

50.8

4.8

28.6

B1 C1 A1

B2

5.6

63.5

57.9

44.5

SPACER - DISCARD IF BOTTOM MANIFOLD MOUNTED. FOR FILTRATION ADD 11.4 THICK FILTER PLATE

G1/4 PORT BOTH ENDS (WITH ADAPTER)

ILMV560011 REV G

A1- Clamp, Quick Coupler

B1- Unclamp, Quick Coupler

Two-Handed Operating Handle Model No. 45-6005-04 For use with Decoupler Model Number 45-6007-27, 45-6007-28, 45-6007-29, 45-6007-03, 45-6007-30, 45-6007-31, 45-6007-32

G1/4

ILMV560007 REV E

www.vektek.com

Outside US+1-913-365-1045

© Vektek December 2021

Made with FlippingBook - Online catalogs