Vektek Metric Hydraulic Clamping Catalog

Accessory Valves

In The Port Sequence Valves n Installs directly into device port, requires oil feed through manifold mount ports.  Works with Top Flange, Bottom Flange Swing Clamps, Link Clamps and New High Capacity Work Supports. n Controls timing of individual devices on your fixture. n Each valve can be individually adjusted from the factory preset. n True sequencing design allows full system pressure downstream of valve after opening. n Maintains pressure upstream while device actuates. n Three pressure ranges available with adjustability within each range.* n Can be added after the fixture is built to assure proper sequencing (Requires the use of flange manifold feed ports). n Use with single or double acting clamps; in clamp port, unclamp port, or both. n Internal reverse free flow check valve allows for faster return. n Accessories available; Pressure pre-set block and in-line adapter block.

PORT DEPTH

A MAX

4mm HEX

B

G

PORT SIZE

F

E

C

ILMV470201 REV D

U.S. Patent No. 11,097,389

Dimensions

Factory Preset Pressure

Set Pressure Range 20-60 bar

Model No.

Port Size X Depth

A B C E F G

47-0443-30 50 bar

28

20.3

G 1/8 x 15.16

16

17.5 5.6 14

47-0443-31 100 bar 35-150 bar 47-0443-32 200 bar 125-275 bar

31.7

24

47-0443-50 50 bar

20-55 bar

34.5

27.4

G 1/4 x 18.72

19

21.0 5.0 17

47-0443-51 100 bar 35-150 bar 47-0443-52 200 bar 125-275 bar

31.8 24.6

Note: Max flow not to exceed the individual device rating or 3.81/min whichever is lower. Maximum inlet pressure for in-port sequence valve is 350 Bar, excess voids warranty. Consult the double acting work support, high capacity work support, the swing clamp or link clamp specifications page for the valve that is appropriate for your application. *Number of sequences within each range depends on number of devices, pump flow & operating pressure.

Valve Pressure Pre-Set Block

Pre-Set Block Model No. 43-3011-70

Presets all G 1/4, G 1/8 and SAE 4 sequence and flow control valves.

M-3

In the Port Sequence Valve In-Line Adapter Block

In-Line Adapter Block

Port x Depth

Model No.

Port X Depth

Inlet/ Outlet

A C 43-1941-00 G 1/8 x 15.16 G 1/8 41.3 22.2 22.2 43-1961-00 G 1/4 x 18.72 G 1/4 54.0 28.6 25.4 B

Inlet Port

Outlet Port

C

A

B

In the Port Cavity Dimensions

ILMV470203 REV A

Cavity Dimensions

OIL INLET ( 2.5 MIN)

J MAX

THREAD F

SPOT FACE

E 0.25

H MIN

Model No.

Size A

C E F G H J K

1.6

B

OIL OUTLET ( 2.5 MIN)

47-0203-71 47-0443-3X 47-0203-74 47-0443-5X

1/8-28 BSPP 1/4-19 BSPP

G 1/8 8.84 15.16 9.9 16.5

8.5 6 12.83 7

A 0.13 THREAD MINOR

K MAX

G 1/4 11.89 18.72 13.3 21.5

12.5 10 16.39 10

Note: Max flow rate not to exceed the individual device rating or 3.8 l/min whichever is lower.

90

G +0.8 / -00 THREAD DEPTH

0.25 0.13

B 0.08

C 0.25 X 90

ILMV702004 REV C

© Vektek December 2021

Inside US 1-800-992-0236

www.vektek.com

Made with FlippingBook - Online catalogs