Vektek Metric Hydraulic Clamping Catalog

Accessory Valves

Pilot Operated Check Valve

58.4

35.4

12.4

G 1/8 PILOT PORT

A

E D

C

MANIFOLD PILOT PORT H

MANIFOLD INLET PORT H

F

MANIFOLD OUTLET PORT H

B

J

INLET PORT G

28.6

L M

OUTLET PORT G

COUNTERBORE TYPE 47-0331-70

L M

Pilot Operated Check Valve n Cartridge and Manifold Mount versions. n Sealed pilot piston eliminates cross circuit leakage. n 5:1 Ratio of Pilot to Check pressure for release. n Unclamp device sequencer, provides a way to sequence single circuit unclamp timing. n Flows up to 5.7 l/min at 350 bar maximum pressure. n Stainless steel cartridge construction.

7.2

ILMV703300 REV C

K

62.7

69.9

94.2

Dimensions Model No. Mounting Style A B C D E F G H J K L M 47-0331-71 Manifold G 1/4 50.8 41.3 25.4 42.1 39.7 8.7 G 1/4 M8 Plug 26.9 28.6 7.1 11.1 47-0331-70 Manifold Only 44.5 38.1 22.2 38.9 36.5 5.5 N/A N/A 23.8 N/A 7.1 11.1

M-8

For proper sealing, the mating surface must be flat within 0.08 mm with a maximum surface roughness of 1.6 µm R a

Mounting Dimensions for Pilot Check Valve P/N 47-0331-70 and 47-0331-71

55.55

50.32

27.31

4.29

14.27

3.30 2.29 3 PLACES FOR MANIFOLD PORTING

16.68

33.35

4X M6 MOUNTING HOLES THREAD 9.65 MINIMUM THREAD DEPTH

PILOT PORT

INLET PORT

OUTLET PORT

ILMV703303 REV B

www.vektek.com

Outside US+1-913-365-1045

© Vektek December 2021