Vektek Metric Hydraulic Clamping Catalog

Work Supports

High Capacity, Fluid Advance

Replace older models with higher capacity cartridges or complete with bases! Normally retracted plungers do not interfere with part loading. Advance them with hydraulic pressure, exerting only spring force to bring the plunger into contact with your part. Hydraulic pressure then automatically sequences, "freezing" the plunger properly against the part.  Available in 8.9 kN or 17.8 kN capacity.  Order with base or cartridge only.  Ventless configuration and built in wipers protect the plunger movement from chips and debris.  Up to 3X capacity of competitor’s version.  Uses Vektek’s BHC technology to guard against corrosion. n O-Ring face seal design makes machining cavities easier. Standard G Series and alternate O-Ring manifold face seal is located in the base of the support for bolt down installation. The base can be removed for direct cartridge mounting.

B-3

ILMV100718 REV E U.S. PATENT NO. 10,799,992

Specifications

Base Dimensions (mm)

Retracted Height (mm)

Working Oil Capacity** (cm 3 )

Contact Force (N)

Direct Replacement for Older Model

Support Capacity (kN)*

Stroke (mm)

Mounting Style***

Model No.

Fluid Advance Work Supports, hydraulic pressure pushes a spring which lifts plunger, hydraulic pressure locks in place.

41-0706-10 41-0071-04 41-0706-16 41-0070-14 41-0806-10 41-0070-04 41-0806-16 41-0071-14 41-0706-17 41-0171-12 41-0708-10 41-0071-03 41-0708-16 41-0071-13 41-0808-10 41-0070-03 41-0808-16 41-0070-13

8.9 8.9 8.9 8.9 8.9

Cartridge Cartridge Manifold Manifold

6.5

54.2

0.8 1.8 .08 1.8 .08 3.3 5.8 3.3 5.8

4.4-26.7

N/A

12.5

67

6.5

62.5 72.5

4.4 - 26.7

23 x 33.5 x 44.5

12.5

Cartridge 4.4 - 26.7 12.5 Cartridge 13.5 - 44.5 6.5 Cartridge 13.5 - 44.5 12.5

67

17.8 17.8 17.8 17.8

N/A

72.5

85

6.5 12.5

82.5 95.3

Manifold Manifold

31.5 x 41.5 x 58.5

13.5 - 44.5

* Support capacities are listed at 350 Bar maximum pressure. Support capacities for other pressures are shown in the fluid advance High Capacity and Part Present Sensing load capacity chart. ** Restrict flow rate to a maximum of 2.13 l/min. *** For cartridge mount models, see cavity dimensions drawings in this catalog section. **** For complete dimensions, see fluid advance work supports (Section B) NOTE: The maximum system back-pressure a fluid advance work support can overcome is 0.7 bar (0.07 MPa) Returning back-pressure greater than 0.7 bar (0.07 MPa) may cause slow or failed retraction.

© Vektek December 2021

Inside US 1-800-992-0236

www.vektek.com

Made with FlippingBook - Online catalogs