Accessory Valves
Pneumatic Confirmation Valve, Block
Confirm Clamp Stroke Position Pneumatically The pneumatic confirmation valve confirms the stage of loading before or after clamping. It is adaptable to multiple devices including: Swing clamps, link clamps, cylinders and work supports. Avoid machine crashes by confirming specific actions before you cycle your machine. It is designed to be used in both coolant and dry environments, and is easily mounted either vertically or horizontally. Confirmation at its finest! n Easily fine tune to your fixture giving you a choice of set and differential pressure. n Confirm signal is based on restricting air flow when tested function is present. n Over-travel sensing will reopen if a device depresses plunger too far on over travel models. n Pneumatic Confirmation Valve can be used with almost any clamping device. n Can help you detect missing or misloaded parts.
Application Setup: Adjust actuator .64± 0.5 above valve body with clamp positioned at the bottom of clamping stroke. This will avoid valve and actuator damage if clamp over travels!
0.64±0.5
CUSTOMER MADE ACTUATOR
A
7
MAX Ø2.8 2X
M4 X .7 7.8 2X
22
ILMV504089 REV A
E
ILMV504086 REV A
31.8 22 35.8
1/8 TUBE - M3 CONNECTOR PART NO. P3037020 AVAILABLE TO PURCHASE WITH PNEUMATIC CONFIRMATION VALVE
A
n Remote venting recommended in coolant applications. n 1/8 Tube - M3 Connector - Part No. P3-0370-20, (Order Separately).
2X M3x.5-6H
7 15.9
1.7 STROKE AIR FLOWS BOTH MODELS
7.3 STROKE NO AIR FLOWS 45-0485-00
E
2X 9.5
NOTE: Mounting hardware not included.
6.3
M3x.5-6H
8
2X 4.7
50.6
8.5 STROKE NO AIR FLOWS 45-0485-01
2X 1.4
10.2 TOTAL STROKE
For proper sealing, the mating surface must be flat within 0.08 mm with a maximum surface roughness of 1.6 µm R a
1.2 STROKE AIR FLOWS 45-0485-00
A Port M3 Plug
5.3
32.9
E Port M3 Plug
29.8
22
4.5
ILMV504085 REV D
NOTE: MOUNTING HARDWARE NOT INCLUDED E = INPUT A = OUTPUT (VENT TO ATMOSPHERE)
M-21
Pneumatic Confirmation Valve
Differential Pressure*
Operating Pressure Range (kPa)
Air Flow Rate (L/Min)
Feed Port Nominal Diameter (mm)
Plunger Stroke (mm)
Max Air Pressure (kPa)
Spring Force (N)
Model No.
Port Types
@140 kPa Air Pressure (kPa)
@480 kPa Air Pressure (kPa)
Description
Over-Travel Sensing
Manifold and M3 Manifold and M3
45-0485-00
1000 70-480 10-20 80 Min.
310 Min.
10 Max 6.6-13.3 2
45-0485-01 Standard 1000 70-480 10-20 80 Min.
310 Min.
10 Max 6.6-13.3 2
* Pressure drop when one or more valves are open. All valves must be closed for pressure confirmation. Plumb multiple valves in parallel.
45-0485-00 Over Travel Sensing Logic
Transition Range
45 - 04X5 - 00 Over Travel Sensing
ON OFF
Air Sensing Control Kit 45-0824-00
CLAMPED
Air Pressure Sensor Switch
Valve Stroke 10.16 2.00 8.25
8.90
Gauge
Swing Clamp Stroke Example
Swing Stroke
Air Supply
Clamping Stroke
Max. 8 Valves
45-0485-01 Standard Logic
Transition Range
45 - 04X5 - 01 Standard
ON OFF
Flow Control Valve Air Pressure Regulator
CLAMPED
Swing Clamp Stroke Example
Valve Stroke 10.16 2.00
Swing Stroke
Clamping Stroke
www.vektek.com ILMV504088 REV B
ILMV504087 REV C
© Vektek December 2021
Inside US 1-800-992-0236
Made with FlippingBook - Online catalogs