Accessory Valves
Pneumatic Confirmation Valve, Cartridge
1.7 STROKE AIR FLOWS BOTH MODELS
7.3 STROKE NO AIR FLOWS 45-0495-00
6.3
26.0
9.3
R.5
8.5 STROKE NO AIR FLOWS 45-0495-01
10.2 TOTAL STROKE
1.2 STROKE AIR FLOWS 45-0495-00
1.7
M12 X 1.5 6H
17.3
RETURN SPRING O-RING
17 HEX
ILMV504096 REV B
M3 X 0.5-6H
18.9
Pneumatic Confirmation Valve Cartridge
Differential Pressure*
Operating Pressure Range (kPa)
Max Air Pressure (kPa)
Air Flow Rate (L/Min)
Plunger Stroke (mm)
Spring Force (N)
Nominal Diameter (mm)
Max Torque (Nm)
Model No.
@140 kPa Air Pressure (kPa)
@480 kPa Air Pressure (kPa)
Description
Over-Travel Sensing
45-0495-00
1000
70-480 10-20 80 Minimum 310 Minimum 10 6.6-13.3 2
25
45-0495-01 Standard
1000
70-480 10-20 80 Minimum 310 Minimum 10 6.6-13.3 2
25
ILMV504095 REV C
* Pressure drop when one or more valves are open. All valves must be closed for pressure confirmation. Plumb multiple valves in parallel.
M-22
20.00
13.00
Outlet port allowable to connect
at any angle to these surfaces
50
2.70
.51 .12
32
17.50 .12
2.0 MAX OUTLET PORT
13.00
45
4.00
23.00 .12
32
M12 X 1.5 6H
Inlet port allowable to connect
5.61 .12
at any angle to these surfaces
2.80 MAX INLET PORT
ILMV504097
REV B
www.vektek.com
Outside US+1-913-365-1045
© Vektek December 2021
Made with FlippingBook - Online catalogs