Work Supports
Air Advance Specifications
For Supporting Fragile Parts Or Use In Harsh Environments n Air Advance Work Supports are available in
B-15
four capacities 4.4 kN to 55.6 kN. Each providing excellent support for light weight or heavy parts and in "hog out" applications.
n Normally retracted plungers provide additional clearance for part loading. Advance them with air pressure, exerting ONLY the force needed to "kiss" the part, then "freeze" the plunger hydraulically. n Heavier attachments may be used with air advance supports because of their additional air powered lifting/contact force. Special large-diameter plungers and sleeves provide greater rigidity. Continuous flow of air, can serve as an "air spring" and be left connected during machining. This "air spring" effect helps keep harsh contaminants from getting between the plunger and sleeve. This is an excellent support choice when using double acting cylinders. You should observe air bubbles escaping around the plunger when used in this manner.
Standard G Series porting and alternate O-Ring manifold face seal is located in the base of the support for bolt down instillation. The base can be removed for direct cartridge mounting.
Air Advance Cartridge Mounted 4.4kN & 11kN
ILMV100600 REV L 33.4kN & 55.6kN Air Advance Base Mounted
Air Advance Base Mounted 4.4kN & 11kN
Specifications
Max. Oil Volume (cm 3 )
Min. Pressure To Fully Extend (Bar)
Maximum Contact Force** (N)
Support Capacity* (kN)
Base Dimensions (mm)
Retracted Height (mm)
Mounting Style***
Hydraulic Connection
Model No.
Stroke (mm)
Air Advance Work Supports, pneumatic advance, hydrauliic lock and spring retract.
41-0060-07 41-0061-07 41-0060-06 41-0061-06
Base
G1/8 Port
24 x 33.5 x 44.5 49.5
4.4
17.5
6.5
0.16
.48
Cartridge Thru Cavity
N/A
41 61
Base
G1/8 Port
25 x 41.5 x 59
11
35.5
9.5
0.33
.69
Cartridge Thru Cavity
N/A
52.5
41-0060-04 33.4 41-0060-05 55.6
Base Base
G1/8 Port G1/8 Port
89
12.5 25 x 63.5 x 76
98
1.64 4.26
1.03
253.5
19 31.5 x 89 x 97 114
.48
* Support Capacities are calculated at 350 bar (35 MPa) maximum operating pressure. Support capacities at other pressures are shown on the Capacity Charts. ** The maximum air pressure recommended for advancing the plunger is 1.7 bar (0.17 MPa). Order air regulator Model No. 50-0440-01 with a 0-1.7 bar (0.17MPa) output, to more precisely control plunger advance force. *** For cartridge mounted models, see the Cartridge Mount Cavity dimensions.
NOTE: Minimum fluid pressure is 52 bar (5.2 MPa)
DIN ISO 2768 T1 and T2 not applicable.
© Vektek December 2021
Inside US 1-800-992-0236
www.vektek.com
Made with FlippingBook - Online catalogs