Vektek Metric Hydraulic Clamping Catalog

TuffCam ™ Swing Clamps and Arms

Top Flange Long Stroke Swing Clamp

Double Acting Long Stroke n Long Stroke Swi ng Clamps are available in 4.9 kN and 11.6 kN capacities. n More than double the vertical clamping stroke for maximum part deviation allowance and swing clearance. n Three cams for accurate arm positioning, smoother rotation and lower per cam surface contact pressure. n Tungsten Carbide ball cam followers for strength and wear. n Patented ball seat for improved rotary function, cam follower contact, and reduced dynamic and static friction. n Same mounting envelope as standard VektorFlo ® Metric Swing Clamps. n To avoid cylinder damage and preserve warranty, use recommended flow rate limits and time calculations at the start of Section C. n Fluorocarbon wipers are standard for improved coolant compatibility.  Standard swing is 90°; swing angles of less than 90° require Swing Restrictors. Swing angles greater than 90° are special order products. n Arm clocking feature is compatible with all standard Vektek arms. Clocking drawing is at the start of Section C. n Arms sold separately – see the end of this section. n Top flange TuffCam ™ swing clamps can be either manifold mounted or standard plumbed.  Optional In-Port Flow Control is a meter-in device with reverse free flow check valve.  Optional In-Port Sequence valve is a sequencing device with reverse free flow check valve.

C-5

U.S. Patent Nos. 6,886,820 7,032,897

ILMV414604 REV G SWING CLAMP PLUNGER SHOWN IN THE EXTENDED LH CAM POSTION

Specifications

Piston Area ( cm 2 ) Retract

Port X Depth for Optional In-Port Valves****

Vertical Clamp Stroke** (mm)

Oil Capacity*** (cm 3 )

Total Stroke (Swing + Vertical) (mm)

Cylinder Capacity* (kN)

Swing Direction

Model No.

Extend Retract

Double Acting (D/A) Cylinders, actuated hydraulically both directions.

41-4605-23 41-4605-24 41-4611-23 41-4611-24

Right

4.9

19

31

1.90

11.96

5.90

G1/8 x 15.16

Left

Right

11.6

34

51

4.04

40.15

20.48

G1/4 x 18.72

Left

WARNING! Never allow swing arm to contact workpiece or fixture during arm rotation. * Cylinder capacities are listed at 350 bar (35 MPa) maximum operating pressure, with a standard length VektorFlo ® arm installed. Minimum operating pressure is 52 bar (5.2 MPa) for single acting, 35 bar (3.5 MPa) for double acting. The clamping force is adjustable by varying the hydraulic system pressure. To determine the approximate output force for your application, divide the cylinder capacity shown above by 350, and multiply the resultant number times your system operating pressure to obtain the approximate clamping force for your application. (Actual force will vary slightly due to internal cantilever loading, friction loss and/or return springs.) ** To allow for workpiece height variations, it is recommended that the vertical travel be set to about 50% of the vertical stroke. *** To ensure maximum service life and trouble-free operation, restrict fluid flow per table at the start of Section C. **** In-Port valves require the use of manifold mount ports.

© Vektek December 2021

Inside US 1-800-992-0236

www.vektek.com