Vektek Metric Hydraulic Clamping Catalog

Tufflink™ 360° Link Clamps

Double Acting Cartridge Mount Design

Single Lever

 Maximum clamping force - minimal footprint.  Levers sold separately.

 Available in 3 sizes, 4.36kN, 6.22kN, and 10.4kN total clamping force at 350 bar.  Cartridge mount body is manifold mount only.  Cartridge mount body minimizes clamp footprint with easy to machine cavity.  Patented rotary lug feature delivers 360 degrees of lever/body positioning.

D-6

U.S. Patent No. 8,678,362

Specifications

Effective Piston Area (cm2 )

Vertical Clamping

Maximum Flow Rate (L/min.) ***

Total Clamping Force (kN)*

LEVERS

Oil Capacity (cm3 )

Model No.

Stroke (mm)**

STANDARD EXTENDED

Extend Extend Retract

Model No.

Double Acting (D/A) Cylinders, actuated hydraulically both directions.

41-6215-30 4.36 41-6218-30 6.22 41-6222-30 10.4

2.5

1.77 2.54

3.5 1.26 6.21 1.90

0.42 91-6115-03 91-6115-02 0.75 91-6118-03 91-6118-02 1.41 91-6122-03 91-6122-02

3

3.5

3.98 11.73 4.22

ILMV166018 REV A SECTION A-A

* Clamp capacities are listed at 350 bar maximum operating pressure with a standard length link clamp lever installed. Minimum operating pressure is 34.5 bar for double acting. The clamping force is adjustable by varying the hydraulic system pressure. Use of an extended length lever will result in a reduction of clamp force. (Actual force will vary slightly due to mechanical inefficiencies, and friction.) ** Equal to ±3° with standard lever. *** To ensure maximum service life and trouble-free operation, restrict fluid flow to the above flow ratings when clamping. If you are unable to measure flow rates, these devices should be positioned in no less than 1/2 second. These recommendations apply when using the standard lever. When using the optional extended lever or your custom lever, please restrict the flow rates to position the lever in no less than 1 second.

B

C

13 CLAMP ANGLE

E

AG

A THREAD D

AD

AH

AB

T

M CLAMP STROKE N

TOTAL STROKE

K

J

H

G HEX

L

F

AF

For proper sealing, the mating surf ace must be flat within .0508mm. with a maximum 1.6 μ m R a surface finish.

ILMV166012 REV B

Dimensions (mm)

Model No.

A B C D E

F G H J

K L M N

Double Acting (D/A) Cylinder, actuated hydraulically both directions. 41-6215-30 M45 X 1.5 108.97 90.85 34.85 72.85 14.99 50 11.99 3.97 42.1 31.68 19.81 23.37 41-6218-30 M50 X 1.5 128.78 104.45 37.65 84.45 18.8 63 15.01 4.78 48.1 32.90 24.38 28.19 41-6222-30 M56 X 1.5 148.08 121.55 38.36 96.55 24.69 75 18.01 5 54.1 33.36 29.46 34.04

Model No. T AB AD AF AG AH Double Acting (D/A) Cylinder, actuated hydraulically both directions. 41-6215-30 55.58 41.5 18 78.82 56.82 27 41-6218-30 69.85 51 19 92.43 64.95 30.51 41-6222-30 82.55 59 19 106.56 73.56 37.01

© Vektek December 2021

Inside US 1-800-992-0236

www.vektek.com

Made with FlippingBook - Online catalogs