Vektek Metric Hydraulic Clamping Catalog

Link Clamps

Link Clamp Specifications

Single and Double Acting  Available in sizes from 1.5 kN to 22 kN capacities at 350 bar (35 MPa) maximum operating pressure.  Single piece body/pivot design for accuracy and long life.  Link clamps clear large obstructions better than other types of clamps.  Pivot pins are corrosion resistant and heat treated.  Manifold mounted or standard plumbed using G1/4 or G1/8 S-Series fittings (face seal Model No. 39-0510-25 included).  Fluorocarbon seals are available on request.  Levers sold separately – see Section P.  Optional In-Port Flow Control is a meter-in device with reverse free flow check valve.  Optional In-Port Sequence valve is a sequencing device with reverse free flow check valve.

D-12

Single Acting

Double Acting

ILM166001 REV G

Specifications

Port X Depth for Optional In-Port Valves**** G1/8 x 15.16 G1/8 x 15.16 G1/4 x 18.72 G1/4 x 18.72 G1/8 x 15.16 G1/8 x 15.16 G1/4 x 18.72 G1/4 x 18.72

Vertical Clamp Stroke** (mm)

Standard Lever Length (mm)

Maximum Flow Rate*** (l/min)

Oil Capacity (cm 3 )

Effective Piston Area (cm 2 )

Cylinder Capacity* (kN)

Model No.

Body Thread

Extend Extend Retract Single Acting (S/A) Cylinders, actuated hydraulically one direction spring returned.

41-6610-40 1.5

2.3 M28 x 1.5 - 6G 22.4 3.1 M38 x 1.5 - 6G 28.7 3.6 M48 x 1.5 - 6G 35.1 4.6 M65 x 1.5 - 6G 44.5

0.49 0.97 1.98 5.06

1.69 N/A 4.70 N/A 13.45 N/A 35.20 N/A

0.20 0.56 1.61 4.23

41-6610-60 41-6610-90

3 6

41-6611-40 13

Double Acting (D/A) Cylinders, actuated hydraulically both directions.

41-6620-40 41-6620-60

2 5

2.3 M28 x 1.5 - 6G 22.4 3.1 M38 x 1.5 - 6G 28.7 3.6 M48 x 1.5 - 6G 35.1 4.6 M65 x 1.5 - 6G 44.5

0.71 1.60 3.88 7.92

1.69 0.52 4.70 1.85 13.45 6.64

0.20 0.56 1.61

41-6620-90 11 41-6621-40 22

35.20 12.67 4.23

* Clamp capacities are listed at 350 bar (35 MPa) maximum operating pressure with a standard length link clamp lever installed. See graph in Section P for clamping force with various lever lengths. Minimum operating pressure is 52 bar (5.2 MPa) for single acting and 35 bar (3.5 MPa) for double acting devices. The clamping force is adjustable by varying the hydraulic system pressure. (Actual force will vary slightly due to mechanical inefficiencies and friction.) ** Equal to +/- 3˚ with standard lever. *** To insure maximum service life and trouble-free operation, restrict fluid flow to the above flow ratings when clamping. If you are unable to measure flow rates, the devices should be positioned in no less than 1/2 second. These recommendations apply when using the standard lever. When using the optional long lever or your custom lever, please restrict the flow rates to position the lever in no less than 1 second. **** In-Port valves require the use of manifold mount ports.

© Vektek December 2021

Inside US 1-800-992-0236

www.vektek.com

Made with FlippingBook - Online catalogs