Link Clamps and Levers
Cartridge Mount Twin Lever Cavity Dimensions
A THREAD UN-2B MINOR C.178 90° X E
.05
.05 A
(D MIN) (D MAX)
F MAX ON OR INSIDE G RADIUS CLAMP FEED
B
D-3
R.51 MAX
A
1.6
(J RADIUS)
(G RADIUS)
H MAX ON J RADIUS UNCLAMP FEED
3.81 MIN 2PLCS
ILMV166015 REV B
Dimensions (mm)
INSTALLATION TORQUE
Model No.
A B CDMINDMAXE F GH J
Cartridge Mount, TL360 Link Clamp
41-6215-40 M45 X 1.5 3.1 44.98 12.7 41-6218-40 M50 X 1.5 3.1 48.46 16 41-6222-40 M56 X 1.5 3.1 54.46 19.1
33.3 45.8 6.35 4.8 3.99 14.25 35.8 50.8 6.35 6.4 4.78 16.71 37.1 56.8 6.35 8.66 4.78 18.42
150 N*M 200 N*M 270 N*M
Proper Clamping for Twin Lever Link Clamps
CORRECT
HEIGHT WITHIN 1.524mm
DRAFT ANGLE
PARALLEL SURFACES
CORRECT
INCORRECT
HEIGHT WITHIN 0.060”
COLLISION POINT
DRAFT ANGLE
PARALLEL SURFACES
www.vektek.com
Outside US+1-913-365-1045
© Vektek December 2021