Link Clamps and Levers
Double Acting Top Flange Twin Lever Design Top Flange Mounted
Made possible by Vektek’s equalizing system!
Top flange body can be manifold mounted or plumbed. Optional In The Port Flow Control is a meter-in device with reverse free flow check valve. Optional In The Port Sequence Valve is a sequencing device with reverse free flow check valve. Levers sold separately, see end of section. Levers must clamp on flat surface
Patented rotary lug feature delivers 360 degrees of lever/body positioning. This simplifies internal porting and fixture design flexibility. Available in 3 sizes, 1100lb, 1700lb, and 2600lb total clamping force at 5000 PSI. Significantly increased vertical clamping stroke over standard link clamp allows access to clamp through a hole onto the surface of work piece. Clamp on two parts with one link clamp. Load equalizing mechanism allows uniform clamping when work piece surfaces are within 0.060 inches.
D-5
U.S. Patent No. 8,678,362
* Clamp capacities are listed at 5000 PSI maximum operating pressure with a standard length link clamp lever installed. Total clamping force is divided equally between each side. Minimum operating pressure is 500 PSI for double acting. The clamping force is adjustable by varying the hydraulic system pressure. Use of an extended length lever will result in a reduction of clamp force. (Actual force will vary slightly due to mechanical inefficiencies, and friction.) ** Equal to ±10° with standard lever. *** To ensure maximum service life and trouble-free operation, restrict fluid flow to the above flow ratings when clamping. If you are unable to measure flow rates, these devices should be positioned in no less than 1/2 second. These recommendations apply when using the standard lever. When using the optional extended lever or your custom lever, please restrict the flow rates to position the lever in no less than 1 second.
Specifications
Effective Piston Area (sq. in.)
Vertical Clamping Stroke (in.)**
Oil Capacity (cu. in.)
Maximum Flow Rate*** (cu. in./min.)
Clamp Capacity (lbs.)*
Model No.
Extend Extend Retract Double Acting (D/A) Cylinders, actuated hydraulically both directions. 16-3215-20 1,100 0.18 0.274 0.141 0.051 17 16-3218-20 1,700 0.24 0.394 0.259 0.080 31 16-3222-20 2,600 0.29 0.616 0.511 0.186 61
Port Depth for Optional In-Port Valves: SAE 4 X .58 In-port valves require the use of manifold mount ports
ILS160012 REV B
Force equally divided between each side
B
AA UNCLAMP PORT W UNCLAMP MANIFOLD PORT O-RING
C
T
Y
V
E
AG
10 CLAMP ANGLE
D
L
AH
AB CONTACT
Q POINT
X
A
P
Z
R
AB CONTACT POINT
AA CLAMP PORT
AD
G
K THRU J
W CLAMP MANIFOLD PORT O-RING
F
H
N TOTAL STROKE
S
M CLAMP STROKE
For proper sealing, the mating surface must be flat within .003 in. with a maximum 63 µin R a surface finish.
AF
ILS160013 REV A
Dimensions (in.)
Model No.
A B
D E F G
C
H J
K L
M N P
Q R
Double Acting (D/A) Cylinders, actuated hydraulically both directions. 16-3215-20 1.408 2.94 2.64 1.008 2.09 1.28 0.67 0.47 0.38 0.22 0.88 0.51 0.64 1.969 0.984 0.797 16-3218-20 1.566 3.35 2.99 1.248 2.34 1.32 0.67 0.59 0.44 0.28 0.83 0.65 0.86 2.441 1.220 0.985 16-3222-20 1.881 3.76 3.31 1.508 2.54 1.34 0.67 0.71 0.53 0.34 0.75 0.83 1.07 2.953 1.476 1.188 S T V W X Y Z AAABADAFAGAH 16-3215-20 0.797 2.402 0.984 2-011 0.433 1.093 0.43 SAE 4 1.38 54 2.283 1.555 0.846 16-3218-20 0.985 2.835 1.220 2-011 0.551 1.289 0.55 SAE 4 1.70 56 2.559 1.654 1.063 16-3222-20 1.188 3.445 1.476 2-011 0.630 1.644 0.63 SAE 4 2.03 54 2.874 1.752 1.201 Model No.
© Vektek, July 2024
800-992-0236
www.vektek.com