Vektek Inch Hydraulic Clamping Catalog

Special Use Clamps

ID Expansion Clamps

Double Acting  Ideal for clamping in blind holes or bore holes.  Save hours and fatigue by not manual clamping.

 Consistent clamping force without the use of a torque wrench.  Range of expansion .010 to .015 depending upon size.  Mandrel can be modified to fit application***  All cylinder pistons are chrome plated, hardened alloy steel.

E-7

F

ILS155205 REV A SECTION A-A

Effective Piston Area (sq. in.)

Oil Capacity (cu. in.)

Hole Size On Part***

Radial Clamping Force (lbs)*

Stroke of Cylinder

Replacement Parts

Model No.

Max Min Extend Retract Extend Retract Pull Bolt** Mandrel****

Double Acting (D/A)

Cylinders, actuated hydraulically both directions.

15-5206-00 15-5210-00 15-5210-01 15-5214-00 15-5217-00 15-5222-00

700

.13 .25 .25 .25 .38 .38

.49 .28 .31 .20 .04 .03 21-4110-47 91-5506-00 .56 .48 .79 .59 .20 .15 21-4110-48 91-5510-00 .79 .53 .79 .59 .20 .15 21-4110-49 91-5510-01 1.06 .71 1.48 1.04 .37 .26 21-4110-50 91-5514-00 1.39 .90 2.41 1.80 .90 .68 21-4110-51 91-5517-00 1.65 1.15 4.43 3.44 1.66 1.29 21-4110-52 91-5522-00

1700 1300 2900 3600 7900

* Holding forces are listed at 5000 PSI operating pressure. The minimum operating pressure is 500 PSI for D/A operation. The holding force is adjustable by varying the hydraulic pressure to the cylinder. To determine the approximate holding force for your application, divide the holding force shown above by 5000 PSI, and multiply the resultant by your system pressure in PSI to obtain the approximate holding force for your application. (Actual forces will vary slightly due to internal friction.) ** At full cylinder capacity, fastener life will be limited and fasteners should be considered service items. Fasteners should be replaced frequently when operating at full capacity to avoid plunger damage. *** Mandrel diameter on clamp is shipped at max hole diameter. Mandrel can be machined down not to exceed min hole diameter to fit each application. Design should ensure that mandrel does not expand more than 0.010” for model 15-5206-00, 0.013” for model 15-5210-00, and 0.015” for models 15-5210-01, 15-5214-00, 15-5217-00, 15-5222-00 **** Replacement Mandrel comes with pull bolt.

Dimensions Model No.

C*

A B

D E

F

G H

J

K

MAX MIN

15-5206-00 2.23 3.05 .49 15-5210-00 2.62 3.51 .56 15-5210-01 2.86 3.57 .79

.28 .010 .48 .013 .53 .015

.63 .75 .75 .88

.59 .59 .59 .69 .81

.76 .88 .88

1.17 1.24 1.48 1.97 2.21 2.74

2.190 2.580 2.816 3.315 3.552 4.300

.25 .25 .25 .25 .25 .25

15-5214-00 3.36 3.88 1.06 .71 .015

1.03 1.12 1.46

15-5217-00 3.59 4.57 1.39 .90 .015 1.00

15-5222-00 4.34 5.21 1.65 1.15 .015 1.25 1.06

© Vektek, January 2023

800-992-0236

www.vektek.com

Made with FlippingBook - Online magazine maker