Clamping Force Tables and Graphs

5000 PSI Twin Lever Link Clamp Clamping Force Output Curves

How to Use the Clamping Force Graphs 1) Start by choosing the lever length you need for your application. 2) Then move along the line and select the clamping force and operating pressure or operating pressure and clamping force needed. Example: Using a 16-3212-00 with a 1.38 in. lever; the clamping force would be 483 at 4000 psi. • The tables and graphs show the relationship between lever length, operating pressure and clamping force. • The lever lengths shown in red bold are Vektek’s available levers for purchase. See page D-20 for details. • The lever lengths shown in parenthesis are the usable length from the edge of the clamp body to the contact bolt. • The row across the bottom of the table is the maximum operation pressure allowed for the associated lever length. • The column on the right of the table is the minimum lever length allowed at the associated operation pressure. • Using the clamp in the Non-Usable range will damage clamp and void product warranty.

D-19

16-3X12-00

0 100 200 300 400 483 600 700 800 900

Non-Usable Range

L = .94 (.11)

E

L = 1.19 (.36)

L = 1.38 (.55)

L = 1.63 (.80)

L = 2.00 (1.17) L = 2.40 (1.57) L = 3.25 (2.42) L = 4.00 (3.17)

4000

0 1000 2000 3000

5000

Operating Pressure (PSI)

ILS916013 REV B

16-X215-20

16-X218-20

Non-Usable Range

Non-Usable Range

1000 1200 1400 1600

2400

L = 1.10

L = .88

2000

L = 1.48

L = 1.75 L = 2.25 L = 3.00 L = 1.30 L = 1.50 L = 1.18

1600

L = 1.00

L = 1.25

L = 2.50 L = 3.00 L = 4.00 L = 2.00 L = 1.75

1200

0 200 400 600 800

800

400

0

0 1000 2000 3000 4000 5000 Operating Pressure (PSI)

0

1000 2000 3000 4000 5000 Operating Pressure (PSI)

ILS916019-15 REV B

ILS916019-18 REV B

16-X222-20 L = 1.30

Non-Usable Range

3500

3000

L = 1.73

2500

L = 1.50

L = 4.00 L = 5.00 L = 3.00 L = 2.38 L = 2.00

2000

1500

1000

500

0

0

1000 2000 3000 4000 5000 Operating Pressure (PSI)

ILS916019-22 REV B