Link Clamps and Levers
Low Pressure Levers and Self Produced Dimensions
B
A
R Threads
G .0005 -A-
H±.005
J±.005
Q
C
L
E
D-24
F TYP
E
K .0005 .001 A
S
Sq Head Set Screw
Full Radius
N
M
D
T HEX
ILS916003 REV F
Dimensions Lever Model No.
For Link Clamp Model No.*
A B C D E F G H J
K L M N Q R
S T
Standard Length Lever 91-6011-03 16-6211-0X 1.69 1.88 0.75 0.50 0.19 0.19 0.2515 0.75 0.13 0.2505 0.50 0.26 0.50 1.25 1/4-20 UNC .19 0.433 91-6015-03 16-6215-0X 2.25 2.63 1.00 0.75 0.31 0.31 0.3765 1.00 0.31 0.3755 0.75 0.39 0.69 2.25 3/8-16 UNC .28 0.557 91-6021-03 16-6221-0X 2.69 3.09 1.25 0.88 0.38 0.38 0.5015 1.19 0.38 0.5005 0.94 0.45 0.88 3.00 1/2-13 UNC .38 0.743 Extended Length Lever without Tapped Hole 91-6011-02 16-6211-0X N/A 3.00 0.75 0.50 0.19 0.19 0.2515 0.75 0.13 0.2505 0.50 0.26 0.50 N/A N/A N/A N/A 91-6015-02 16-6215-0X N/A 3.50 1.00 0.75 0.31 0.31 0.3765 1.00 0.31 0.3755 0.75 0.39 0.69 N/A N/A N/A N/A 91-6021-02 16-6221-0X N/A 4.00 1.25 0.88 0.38 0.38 0.5015 1.19 0.38 0.5005 0.94 0.45 0.88 N/A N/A N/A N/A
*Link Clamps to be ordered separately.
Low Pressure Link Clamp Lever Output Curves (Double Acting Only)
NOTE: Modifications to levers that result in clamp ratios below a 1:1 ratio are not in the safe operating zone for the corresponding link clamp and could result in premature failure. Exceeding the allowable offset values and operating pressures specified in the tables will result in excessive forces on the link clamp pins, links and rod which could result in premature failure.
www.vektek.com
800-992-0236
© Vektek, July 2024
Made with FlippingBook - Online magazine maker