Vektek Inch Hydraulic Clamping Catalog

Compact Clamps

Compact Clamps with Pneumatic Sensing Information

Patent Pending

Double Acting Compact Clamp with Pneumatic Sensing Engineered to use air pressure to provide clamp position feedback to machine systems. Once clamped, air pressure will build up to the set point.  All of the same features you love about the compact clamp, with the bonus of pneumatic clamp confirmation!  Pneumatic Sensing will show a change in air pressure if the clamp overtravels or is not in clamped position.  Use with Vektek’s Air Sensing Control Kit 50-8240-00.

BTM M1 M2 TOP

SEE NEXT PAGE FOR TOP&BTM STROKE DIMS AIR PRESSURE BUILDS BETWEEN POINT M1&M2

E-3

F

ILS175201 REV A

Patent Pending

Oil Capacity (in 3 )*** POINT M1

Effective Piston Area (in 2 )

Sensing Range (in)

Vertical Clamp Stroke (in.)**

Total Stroke (Flipback + Vertical) (in)

Maximum Flow Rate (in 3 /min) ***

Clamp Capacity (lbs.)*

Sensing Stroke (in)

Model No.

POINT M2

Bottom (M1)

Top (M2)

Retracted Extended Retracted

15 PSI

Double Acting (D/A)

Cylinders, actuated hydraulically both directions.

BTM M1 M2 TOP

17-5217-00-PP

750

.19 .21 .29 .30

.09 .11 .14 .20

.59 .76 .95

.223 .293 .482 .789

.196 .131 .370 .221 .747 .456 1.352 .859

16 27 55

.35 .44 .37 .48 .47 .61 .50 .70

2 PSI

17-5220-00-PP 1,000 17-5225-00-PP 1,750 17-5232-00-PP 2,750

104 POSSIBLE OVERTRAVEL (AIR FLOWS)

CLAMP (NO AIR FLOWS)

UNCLAMP (AIR FLOWS)

1.10

SEE NEXT PAGE FOR TOP&BTM STROKE DIMS AIR PRESSURE BUILDS BETWEEN POINT M1&M2

Warning! Never allow arm to contact workpiece or fixture during actuation. * Cylinder capacities are listed at 5,000 psi maximum operating pressure, with a short arm installed. Minimum operating pressure of 500 psi is required for double acting applications. The clamping force is adjustable by varying the hydraulic system pressure. to determine the approximate clamping force for your application, see IS1776. ** To allow for piece part height variations, it is recommended that the vertical travel be set at about 50% of the vertical stroke. *** To ensure maximum service life and trouble-free operation, restrict fluid flow to the above flow ratings. If you are unable to measure flow rates, adjust flow so that the clamping action occurs in no less than half a second. If using extended arm either quarter the above flow rates, or time clamping action to be no less than two seconds. ILS175201 REV A

POINT M1

POINT M2

15 PSI

2 PSI

POSSIBLE OVERTRAVEL (AIR FLOWS)

CLAMP (NO AIR FLOWS)

UNCLAMP (AIR FLOWS)