For proper sealing, mating surfaces must be flat within 0.003 in. with a maximum 32 µ in. R a surface finish.

Operating Parameter Guidelines - Operating Temperature Range: 40°-160°F - Max. RPM see table - Air may be run in any available passage

- Rotating unions are not intended to be a structural member. It is recommended that the anti-rotate arm should be fully supported by external framework. Load on the union should be minimized. Please contact Vektek for technical assistance. - Installation Instructions Available, Request IS3207

2X C Port Plugged at assembly. For manifold mounting models 32-2242 and 32-2262-02, order two each adapter 30-8711-23 and discard the plugs. Model numbers ending in -03 are not manifold mountable. See Note.

N

Body Port A Body Port B

E

Locator Hole .218 .41

D

Base Port A

F

45

45

45

G

.375

H

A

K

P

B

I-6

Circle S Bolt

Circle J Bolt

F Equal sp

.13

Base Port B

4X 1/4 Cap Screw mounting holes Equal sp on J Bolt Circle

2X 3/8-16 UNC .50 Equal sp on S Bolt Circle

L

2X 5/16 Cap Screw mounting holes Equal sp on S Bolt Circle

M

B

ILS321205 REV V

A

Dual Path Dimensions Model No.

A B C D E F G H J

K L M N P S

Adapter Model No. 30-8711-23 is needed for manifold mounting. Order Separately. 32-2242-02 2.97 1.06 SAE 2 0.50 1.56 SAE 4 1.44 1.156 2.50 3.00 1.51 0.77 2.28 0.28 2.31 32-2262-02 3.34 1.13 SAE 2 0.63 1.73 SAE 6 1.68 1.375 3.00 3.50 1.82 0.84 2.57 0.38 2.75 Models 32-2242-03 and 32-2262-03 are not adaptable for manifold mounting. 32-2242-03 3.06 1.16 SAE 4 0.60 1.65 SAE 4 1.44 1.156 2.50 3.00 1.51 0.87 2.37 0.39 2.31 32-2262-03 3.34 1.13 SAE 6 0.63 1.73 SAE 6 1.69 1.375 3.00 3.50 1.82 0.85 2.57 0.47 2.75

Operating Limits

100 150 200 250 300 350 400

100 120 140

0 20 40 60 80

32-2262-02 & 32-2262-03

32-2242-02 & 32-2242-03

0 50

0 1000 2000 3000 4000 5000 Input Pressure (psi)

0 1000 2000 3000 4000 5000 Input Pressure (psi)

NOTE: Torque requirements may vary depending on port configuration and pressure run through ports. Testing of your specfic application may be required.

ILS321212 REV B

www.vektek.com

800-992-0236

© Vektek, January 2023