Rotary Unions and Arm
Rotating Union, 12 Path
12 Path Rotating Unions
.38 Thru
12X SAE 4
12X SAE 4
15
12 X .19 Thru oil passage, manifold mount models only.
2.375 B.C.
1.93
4X 1.27
.72
11X 30
1 3 5
7 9 11
1.062 B.C.
3X
90
2.94
6X 60
1.562 B.C.
45
8 10 12
2 4 6
3.44
5X 60
.812
4X 1.27
4X 1/4-20 .50
30
2.57
3.000 B.C.
5.82
1.35
12X 1/4-20 .75
10.80
6X 60
12 X .19 Thru oil passage
30
A
Optional 6 or 12 Circuit Electrical Slip Ring: -Aluminum Slip Ring Cap -Water Tight Pin Connector -48 in. Lead Wire
1.562 B.C.
5X 60
4.44
1.062 B.C.
(48)
4.000
11X 30
B.C.
Optional 6 or 12 Pin x 32 ft. Cordset -Ordered Separately See Table
.50
12X .26 Thru
15
.56
A
Optional Steel Mounting Flange PN 93-2120-00
SECTION A-A
Operating Parameter Guidelines: - Max. Pressure: 5,000 psi. - Max. Vacuum: 30 Hg.
ILS3211200 REV L
- Max. RPM under vacuum: contact factory. - Max. RPM under pressure: see table on page I-1. - Operating Temperature Range with slip ring: 0° - 176° F. - Max Operating Temperature Range without slip ring 0°- 220° F. - Air may be run in any available passage.
For Proper sealing, mating surface should be flat to 0.003 in. with a maximum 32 µ in. R a surface finish.
I-9
- Rotating unions are not intended to be a structural member. It is recommended that the anti-rotate arm should attach to the stationary part of the union and should be fully supported by external framework. Load on the union should be minimized. Please contact Vektek for technical assistance. - Separate air and fluid with extra passage between them.
12 Path Rotary Unions
Hydraulic Input Connection
Electrical Slip Ring Option
Maximum Current/ Circuit
Optional Flange Model No.**
Model No.
Maximum Volts/Circuit
Lead Wire Length
Optional Cord Set***
32-1224-12
SAE 4 SAE 4
N/A
N/A
N/A
N/A 48” 48”
N/A
32-1224-12-ES6A
6 Circuit 12 Circuit
2 Amp 2 Amp
120 VAC 120 VDC
27-6424-01 27-6424-02
32-1224-12-ES12A SAE 4
O-Ring Face Seal* O-Ring Face Seal* O-Ring Face Seal*
32-1224-13
N/A
N/A
N/A
N/A
N/A
93-2120-00
32-1224-13-ES6A
6 Circuit
2 Amp
120 VAC
48”
27-6424-01
32-1224-13-ES12A
12 Circuit
2 Amp
120 VDC
48”
27-6424-02
Operating Limits Pressure (psi) versus Speed (rpm)
Performance Data Pressure ( psi ) versus Torque ( ft-lb )
*
O-Rings furnished: -009, 70A, NBR (Part No. 39-0500-36)
** Optional Mounting Flange includes:
250 200 150 100 50
100
- 12 SHCS 1/4-20 x 1/2 (Part No. 21-4100-63) - 12 O-Rings -009, 70A NBR (Part No. 39-0500-36) - 1 O-Rings -012, 70A NBR (Part No. 39-0020-09) - 1 O-Rings -013, 70A NBR (Part no. 39-0000-72)
80
60
*** Order cord set separately.
40
0
Installation instructions available. Request IS3205 or visit our online catalog for a link to this document.
20
Input Pressure (psi)
Model No. 32-1224-12
0
ILS321219 REV B 32-1224-13 32-1224-13-ES6A* 32-1224-13-ES12A*
*Max speed for slip ring 100RPM 32-1224-12-ES6A* 32-1224-12-ES12A*
Input Pressure (psi)
Model No. Torque data based on all passages (ports) pressurized.
ILS321216 REV B 32-1224-13 32-1224-13-ES6A 32-1224-13-ES12A
32-1224-12 32-1224-12-ES6A 32-1224-12-ES12A
www.vektek.com
800-992-0236
© Vektek, July 2024
Made with FlippingBook - Online magazine maker