Vektek Inch Hydraulic Clamping Catalog

Palletized Fixture Accessories

Automatic Shutoff Valve Decouplers, One-Handed Operating Handle

Automatic Shutoff Valve Decouplers for Single and Double Acting Systems  Decouplers are a convenient, self-contained package that includes quick connect couplings, filters, pilot operated check valve and an over pressure relief valve.  Robust pilot operated check valve with a 1:5 pilot to check pressure for proven long term reliability.  Internal 25 micron filters for added protection of pilot operated check valve through ports A1, A2, A3, A4 and C1. Additional filtration provided at port B1. Filtration is not provided at ports B2, B3, & B4 due to space constraints and the isolation of the check valve by the actuation piston.  Integral accumulator available in three operating pressure ranges.  SAE ports and manifold mounting (bottom and rear) connections on all models.  Single acting pallet circuits require 2 hoses to the Operating Handle for pressure release. For single hose systems see the Manual Shutoff Valve Decoupler.  Additional filtration available for the B return port through the use of manifold mount and in-line filtration.

NOTE: These automatic shutoff valve decouplers and operating handle must be used with a suitable pump which includes a 4 port/3 position, P-blocked center ("A" & "B" connected to tank) directional control valve for operation of single or double acting systems. See the pump convenience package for the pump model of your choice, “Pallet Decoupler (two hose)” in section J. One automatic shutoff valve decoupler can be used to operate only one double acting or one single acting circuit. For operation of a single acting circuit, plug the decoupler outlet port "B" (as shown in the schematic).

3.12

SAE 6 PORT BOTH ENDS

1.63 3.50

"B1" QUICK CONNECTOR "UNCLAMP"

.40

2.45

1.63

3x MACHINED FOR 1/4 SHCS

2.23

3.50

3.15

"A1" QUICK CONNECT "CLAMP"

2.65

1.30

30

1.06 1.06

37 JIC 7/16-20

.22

2.73

2.28

1.75

3.42

2.50

"B1" QUICK CONNECTOR UNCLAMP "A1" QUICK CONNECTOR CLAMP

3.52

SAE 6 MANIFOLD MOUNT

B1

A1

K-3

4x DRILLED FOR 1/4 SHCS

6.97

TRIGGER PULL BACK TO CONNECT AND DISCONNECT HANDLE. HYDRAULIC PRESSURE MUST BE AT 0 PSI. TO

PLUG "B" PORT FOR S/A SYSTEMS

B3 A3

2.13

1.25

A2 A4

B2 B4

2.27 4.62 4.25 2.27

1.24

CONNECT OR DISCONNECT

.19

.19

ILS560019 REV E

1.20

.80

1.24

 Provides a fast, positive connection to the Decoupler.  Positive lock/un-lock design eliminates missed connections.  Ergonomic design reduces operator fatigue.  Maximum working pressure is 5,000 psi. For use with Decoupler Model Nos. 56-0005-23, 56-0005-24, 56-0005-25 or 56-0005-26, 56-0005-42 or 56-0005-43 One-Handed Operating Handle Model No. 56-0008-00

1.13

B1 A1 C1

MINIMUM OF 20% CLAMP PRESSURE MUST BE APPLIED TO UNCLAMP

2.53

SAE 6 MANIFOLD MOUNT

ILS560024 REV J

Decouplers with Integral Accumulator Model No. Pressure Range (psi) Accumulator Capacity (cu. in.) For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 µ in. R a surface finish.

Optional Filters

Optional In-Line Filter

In-Port (For Manifold Mounting)

Filter Plate (For Manifold Mounting) 70-8420-05 (BOTTOM A4 & B4) OR 70-8420-06 (REAR A3 & B3)

56-0005-42 400-1,500 56-0005-23 1,000-3,500

3.8 3.6

70-0437-71 (Ports A3, B3, B4)

70-0401-71

56-0005-24 2,000-5,000 3.2 For use with Operating Handle Model No. 56-0008-00.

www.vektek.com

800-992-0236

© Vektek, January 2023