Vektek Inch Hydraulic Clamping Catalog

Palletized Fixture Accessories

Automatic Shutoff Valve Decouplers, Two-Handed Operating Handle

Automatic Shutoff Valve Decouplers for Single and Double Acting Systems  Decouplers are a convenient, self-contained package that includes quick connect couplings, filters, pilot operated check valve, an over pressure relief valve.  Robust pilot operated check valve with a 1:5 pilot to check ratio for proven long term reliability.  Internal 25 micron filters for added protection of the pilot operated check valve through ports A1, A2, A3, A4 and C1. Additional filtration at port B1. No filtration at remaining ports.  Integral accumulator available in three operating pressure ranges.  SAE ports and manifold mounting (bottom and rear) connections on all models.  Single acting pallet circuits require 2 hoses to the Operating Handle for pressure release. For single hose systems, see the Manual Shutoff Valve Decoupler in this section.  Additional filtration available through the use of manifold mount and in-line filtration. Filter kit model # 62-5600-05 (for in-line mounting) or 62-5600-06 (for manifold mounting).

New 25 Micron Filters

NOTE: These automatic shutoff valve decouplers and operating handle must be used with a suitable pump which includes a 4 port/3 position, P-blocked center ("A" & "B" connected to tank) directional control valve for operation of single or double acting systems. See the pump convenience package for the pump model of your choice, “Pallet Decoupler (two hose)” in section J. One automatic shutoff valve decoupler can be used to operate only one double acting or one single acting circuit. For operation of a single acting circuit, plug the decoupler outlet port "B" (as shown in the schematic).

.80

3x MACHINED FOR 1/4 SHCS

SAE 6 PORT BOTH ENDS

1.55

A1, Clamp Quick Coupler

1.07

B1, Unclamp Quick Coupler

3.50

1.30

1.06

2.28 1.75

.22

1.13

.17

1.06

2.61

2.64 5.00

.87 .32

2.50

SAE 6 PORT

"B1" QUICK CONNECTON UNCLAMP

"A1" QUICK CONNECTOR CLAMP 4x DRILLED FOR 1/4 SHCS SAE 6 MANIFOLD MOUNT

56-0005-04 DOUBLE ACTING QUICK CONNECTOR HANDLE FOR TWO HANDED OPERATION USED WITH AUTOMATIC SHUTOFF VALVE PALLET DECOUPLER 56-0005-17, 56-0005-18, 56-0005-19, 56-0005-20, 56-0005-40 OR 56-0005-41

RECOMMENDED PUMP CONFIGURATION:

K-5

PLUG "B" PORT FOR S/A SYSTEMS

2.13

A1, Clamp Quick Coupler

B3 A3

B1, Unclamp Quick Coupler

NOTE: THESE AUTOMATIC SHUTOFF VALVE DECOUPLERS AND OPERATING HANDLE MUST BE USED WITH A SUITABLE PUMP (SEE INSET), WHICH INCLUDES A 3-POSITION/4-PORT, P-BLOCKED CENTER ("A" & "B" CONNECTED TO "TANK") DIRECTIONAL CONTROL VALVE FOR OPERATION OF SINGLE OR DOUBLE ACTING SYSTEMS. ONE AUTOMATIC SHUTOFF DECOUPLER CAN BE USED TO OPERATE ONLY ONE DOUBLE ACTING OR ONE SINGLE ACTING CIRCUIT. FOR OPERATION OF A SINGLE ACTING CIRCUIT, PLUG THE DECOUPLER PORT "B" (AS SHOWN IN THE SCHEMATIC). A2 A4

1.25

B2 B4

4.25 2.27 2.27 4.62

1.24

.19

.19

1.24

115 VAC, 1 PHASE P/N 55-9242-09 230 VAC, 3 PHASE P/N 55-9272-09 460 VAC, 3 PHASE P/N 55-9292-09

1.13

B1 C1 A1

SAE 6 PORT

MINIMUM OF 20% CLAMP PRESSURE MUST BE APPLIED TO UNCLAMP

2.53

ILS560007 REV M

56-0005-04 DOUBLE ACTING QUICK CONNECTOR HANDLE FOR TWO HANDED OPERATION USED WITH AUTOMATIC SHUTOFF VALVE PALLET DECOUPLER 56-0005-17, 56-0005-18, 56-0005-19, 56-0005-20, 56-0005-40 OR 56-0005-41

 Provides fast, positive connection to the Decoupler.  The Two-Handed Handle may be used with the optional Handle Docking Module to assure that the hoses are disconnected from the pallet before it is shuttled into the machine. 115 VAC, 1 PHASE P/N 55-9242-09 230 VAC, 3 PHASE P/N 55-9272-09 460 VAC, 3 PHASE P/N 55-9292-09 Two-Handed Operating Handle Model No. 56-0005-04 For use with Decoupler Models 56-0005-17, 56-0005-18, 56-0005-19, 56-0005-20, 56-0005-40 or 56-0005-41 RECOMMENDED PUMP CONFIGURATION:

SAE 6 MANIFOLD MOUNT

ILS560021 REV H

NOTE: THESE AUTOMATIC SHUTOFF VALVE DECOUPLERS AND OPERATING HANDLE MUST BE USED WITH A SUITABLE PUMP (SEE INSET), WHICH INCLUDES A 3-POSITION/4-PORT, P-BLOCKED CENTER ("A" & "B" CONNECTED TO "TANK") DIRECTIONAL CONTROL VALVE FOR OPERATION OF SINGLE OR DOUBLE ACTING SYSTEMS. ONE AUTOMATIC SHUTOFF DECOUPLER CAN BE USED TO OPERATE ONLY ONE DOUBLE ACTING OR ONE SINGLE ACTING CIRCUIT. FOR OPERATION OF A SINGLE ACTING CIRCUIT, PLUG THE DECOUPLER PORT "B" (AS SHOWN IN THE SCHEMATIC).

For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 µ in. R a surface finish. NOTE: For use with Operating Handle Model No. 56-0005-04. May be used in conjunction with Safety Interlock Storage Module Model No. 56-0005-05. Decouplers with Integral Accumulator

ILS560007 REV M

Optional Filters

Optional In-Line Filter

Accumulator Capacity (cu. in.)

Model No.

Pressure Range (psi)

In-Port (For Manifold Mounting)

Filter Plate (For Manifold Mounting) 70-8420-05 (BOTTOM A4 & B4) OR 70-8420-06 (REAR A3 & B3)

56-0005-40 400-1,500 56-0005-17 1,000-3,500 56-0005-18 2,000-5,000

3.8 3.6 3.2

70-0401-71

70-0437-71

www.vektek.com