Power Supplies
Advanced Workholding Pump 1 HP Convenience Package
100-120 VAC 1 Phase
200-240 VAC 3 Phase
380-500 VAC 3 Phase
No. of Valves
2 Port Pump - No Control Valves Included
Valve Type: Manifold Only • Central or remote power supply configured with “P” (pressure out) and “T” (tank return flow) port only. • Valves usually mounted on the machine closer to the application, often machine controlled. • Typically mounted behind or between 2 machines. • Requires remote shear seal or poppet style zero leak valve. • Supply your own off board valve.
0 55-9545-00 55-9575-00 55-9595-00
Single Acting Continuous Connection - S/A Live System Valve Type: Manual 2-Position 3-Port • Can use coupled or uncoupled.
• Recommended to run a continuously connected or single hose supply decoupled system. • Operator interface is a manual valve handle. • Pump located within operators reach. Valve Type: 24VDC 2-Position 3-Port Normally Open
1 55-9545-12-1 55-9575-12-1 55-9595-12-1
• Recommended to run a continuously connected or single hose supply decoupled system where the pressurized time exceeds the unpressurized time. • Operator interface is by remote pendant or can be wired into a machine controller. NOTE: Should not be used with palletized systems as the valve is energized to unclamp. The unclamped time will be excessive, causing the valve to run hot.
1 2 4
55-9545-23-1 55-9545-23-2 55-9545-23-4
55-9575-23-1 55-9575-23-2 55-9575-23-4
55-9595-23-1 55-9595-23-2 55-9595-23-4
J-8
Double Acting Continuous Connection - D/A Live System Valve Type: Manual 3-Position 4-Port Closed Center • Recommended for continuously connected "live" systems.
1 2 4
55-9545-16-1 55-9545-16-2 55-9545-16-4
55-9575-16-1 55-9575-16-2 55-9575-16-4
55-9595-16-1 55-9595-16-2 55-9595-16-4
• Always connected to the fixture by means of hoses and/or rotary unions. • Operator interface is a manual valve handle. • Pump located within operators reach. 24 VDC 3-Position 4-Port Closed Center • Recommended for continuously connected "live" systems. • Always connected to the fixture- by means of hoses and/or rotary unions. • Center position allows no movement of clamps when the valve is de-energized. • Operator interface is by remote pendant or can be wired into a machine controller.
1 2 4
55-9545-26-1 55-9545-26-2 55-9545-26-4
55-9575-26-1 55-9575-26-2 55-9575-26-4
55-9595-26-1 55-9595-26-2 55-9595-26-4
ILS559503 REV C
NOTE: 525-600V, 3-Phase pumps are available upon request.
© Vektek, July 2024
800-992-0236
www.vektek.com