Vektek Inch Hydraulic Clamping Catalog

Power Supplies

Advanced Workholding Pump 1 HP Convenience Package

100-120 VAC 1 Phase

200-240 VAC 3 Phase

380-500 VAC 3 Phase

No. of Valves

2 Port Pump - No Control Valves Included

Valve Type: Manifold Only • Central or remote power supply configured with “P” (pressure out) and “T” (tank return flow) port only. • Valves usually mounted on the machine closer to the application, often machine controlled. • Typically mounted behind or between 2 machines. • Requires remote shear seal or poppet style zero leak valve. • Supply your own off board valve.

0 55-9545-00 55-9575-00 55-9595-00

Single Acting Continuous Connection - S/A Live System Valve Type: Manual 2-Position 3-Port • Can use coupled or uncoupled.

• Recommended to run a continuously connected or single hose supply decoupled system. • Operator interface is a manual valve handle. • Pump located within operators reach. Valve Type: 24VDC 2-Position 3-Port Normally Open

1 55-9545-12-1 55-9575-12-1 55-9595-12-1

• Recommended to run a continuously connected or single hose supply decoupled system where the pressurized time exceeds the unpressurized time. • Operator interface is by remote pendant or can be wired into a machine controller. NOTE: Should not be used with palletized systems as the valve is energized to unclamp. The unclamped time will be excessive, causing the valve to run hot.

1 2 4

55-9545-23-1 55-9545-23-2 55-9545-23-4

55-9575-23-1 55-9575-23-2 55-9575-23-4

55-9595-23-1 55-9595-23-2 55-9595-23-4

J-8

Double Acting Continuous Connection - D/A Live System Valve Type: Manual 3-Position 4-Port Closed Center • Recommended for continuously connected "live" systems.

1 2 4

55-9545-16-1 55-9545-16-2 55-9545-16-4

55-9575-16-1 55-9575-16-2 55-9575-16-4

55-9595-16-1 55-9595-16-2 55-9595-16-4

• Always connected to the fixture by means of hoses and/or rotary unions. • Operator interface is a manual valve handle. • Pump located within operators reach. 24 VDC 3-Position 4-Port Closed Center • Recommended for continuously connected "live" systems. • Always connected to the fixture- by means of hoses and/or rotary unions. • Center position allows no movement of clamps when the valve is de-energized. • Operator interface is by remote pendant or can be wired into a machine controller.

1 2 4

55-9545-26-1 55-9545-26-2 55-9545-26-4

55-9575-26-1 55-9575-26-2 55-9575-26-4

55-9595-26-1 55-9595-26-2 55-9595-26-4

ILS559503 REV C

NOTE: 525-600V, 3-Phase pumps are available upon request.

© Vektek, July 2024

800-992-0236

www.vektek.com

Made with FlippingBook - Online magazine maker