Vektek Inch Hydraulic Clamping Catalog

Power Supplies

Advanced Workholding Pump 2 HP Convenience Package

200-240 VAC 3 Phase

380-500 VAC 3 Phase

No. of Valves

Pallet Decoupler (one hose) S/A

Valve Type: Manual 2-Position 3-Port • Can use coupled or uncoupled.

Recommended to run a continuously connected or single hose supply decoupled system. Operator interface is by a manual valve handle.

1

55-9675-12-1 55-9695-12-1

• •

Pump located within operators reach. Valve Type: 24VDC 2-Position 3-Port Normally Closed "Dump Pump" • Single Acting Decoupled Systems.

Valve installed with a control pendant to power systems using the Self-closing Decoupler and Tombstone Top Plates. Commonly called a "dump pump" and uses a momentary contact pendant switch. When preset pressure is reached the control valve automatically shifts and dumps pressure back to tank.

1

55-9675-25-1 55-9695-25-1

Operator interface is by remote pendant or can be wired into a machine controller. Valve Type: 24VDC 2-Position 3-Port Normally Closed • Single Acting Live systems.

Use with Manual Pallet Decouplers, Tombstone Top Plates and Self-Closing (single hose) Decouplers. Operator interface is by remote pendant or can be wired into a machine controller. All decoupled valves are de-energized when not in use to avoid heat build-up between cycles.

1 2 4

55-9675-24-1 55-9675-24-2 55-9675-24-4

55-9695-24-1 55-9695-24-2 55-9695-24-4

NOTE:

Pallet Decoupler (two hose) S/A or D/A

J-12

Valve Type: Manual 3-Position 4-Port P-Blocked • Double Acting or Single Acting run live or decoupled. 1 • Control Auto-Shutoff Pallet Decoupler. (2 hose system)

55-9675-17-1 55-9695-17-1

Operator interface is a manual valve handle.

• •

Best selection for fixture testing, runs most systems. Valve Type: 24VDC 3-Position 4-Port P-Blocked Center with A & B Individual Circuit Pressure Adjustment • Reduces pressure to clamp or unclamp side of a circuit.

Use with one or two handed Auto-Shutoff Decoupler. P-Blocked center valve drops pressure in both lines. Allows decoupling and re-coupling of the hoses. Operator interface is remote pendant or wired into a machine controller.

• •

1

55-9675-28-1 55-9695-28-1

• This configuration can also be used to operate two individual single acting systems at different pressures. Valve Type: 24VDC 3-Position 4-Port P-Blocked • Double or Single Acting.

Use 1 or 2 handed Auto-Shutoff Pallet Decoupler. Uses a P-Blocked center to drop pressure in both lines to decouple and re-couple hoses. Operator interface is by remote pendant or can be wired into a machine controller.

• •

1 2 4

55-9675-27-1 55-9675-27-2 55-9675-27-4

55-9695-27-1 55-9695-27-2 55-9695-27-4

NOTE: 525-600V, 3-Phase pumps are available upon request.

ILS559604 REV C

© Vektek, July 2024

800-992-0236

www.vektek.com

Made with FlippingBook - Online magazine maker