Power Supplies
Low Pressure Advanced Workholding Pump 2 HP Convenience Package
200-240 VAC 3 Phase
380-500 VAC 3 Phase
No. of Valves
2 Port Pumps - No Control Valves Included
Valve Type: Manifold Only • Central or remote power supply configured with “P” (pressure out) and “T” (tank return flow) port only.
• Valves usually mounted on the machine closer to the application, often machine controlled. • Typically mounted behind or between 2 machines. • Requires remote shear seal or poppet style zero leak valve. • Supply your own off board valve. Single Acting Continuous Connection - S/A Live System
0 55-7675-00 55-7695-00
Valve Type: 24VDC 2-Position 3-Port Normally Open • Recommended to run a continuously connected or single hose supply decoupled system where the pressurized time exceeds the unpressurized time. • Operator interface is by remote pendant or can be wired into a machine controller. NOTE: Should not be used with palletized systems as the valve is energized to unclamp. The unclamped time will be excessive, causing the valve to run hot.
1 2 4
55-7675-23-1 55-7675-23-2 55-7675-23-4
55-7695-23-1 55-7695-23-2 55-7695-23-4
Double Acting Continuous Connection - D/A Live System 24 VDC 3-Position 4-Port Closed Center • Recommended for continuously connected "live" systems.
J-14
• Always connected to the fixture- by means of hoses and/or rotary unions. • Center position allows no movement of clamps when the valve is de-energized. • Operator interface is by remote pendant or can be wired into a machine controller.
55-7675-26-1 55-7675-26-2 55-7675-26-4
1 2 4
55-7695-26-1 55-7695-26-2 55-7695-26-4
Pallet Decoupler - One Hose S/A
24 VDC 2-Position 3-Port Normally Closed • Single acting live systems.
• Use with manual pallet decouplers, tombstone top plates, and self- closing (single hose) decouplers. • Operator interface is by remote pendant or can be wired into a machine controller.
55-7675-24-1 55-7675-24-2 55-7675-24-4
55-7695-24-1 55-7695-24-2 55-7695-24-4
1 2 4
NOTE: All decoupled valves are de-energized when not in use to avoid heat build-up between cycles.
Pallet Decoupler - Two Hose S/A or D/A
Valve Type: 24 VDC 3-Position 4-Port P-Blocked Center • Double or single acting systems. • Use 1 or 2 handed auto-shutoff pallet decoupler. • P-blocked center valve drops pressure in both lines. Allows decoupling and re-coupling of the hoses. • Operator interface is remote pendant or wired into a machine controller.
1 2 4
55-7675-27-1 55-7675-27-2 55-7675-27-4
55-7695-27-1 55-7695-27-2 55-7695-27-4
ILS557603 REV B
NOTE: 525-600V, 3-Phase pumps are available upon request.
© Vektek, July 2024
800-992-0236
www.vektek.com
Made with FlippingBook - Online magazine maker