Vektek Inch Hydraulic Clamping Catalog

Accessory Valves

Pressure Reducing Valve

Pressure Reducing Valve  Control pressure to individual devices.  For use in double or single acting systems.  Direct acting, poppet style, adjustable, cartridge construction.  Cartridge may be installed directly into your manifold.

 Model 70-5410-10 set the pressure range from 750 to 4500 psi. Repeatability ± 7%  Model 70-5410-01 set the pressure range from 150 to 900 psi. Repeatability ± 10%  Maximum inlet pressure 5,000 psi.  Pressure Reducing Cartridge is interchangeable with the Pressure Limiting Cartridge in the same mounting cavity.  Two-port design eliminates need for third fluid line to drain bypass flow (internal leakage) back to system reservoir. n Recommended Filtration: 25 Micron (NOM) /40 Micron (ABS) (minimum). Operation: The Pressure Reducing Valve (PRV) is a Normally Open (N/O) pressure control device. The valve remains open and fluid flows freely to downstream devices (from the valve to devices) until the pressure in the valve reaches the pressure (adjustable) set-point. At the set-point pressure, the valve closes blocking further flow and pressure rise to the downstream devices. If there is a sufficient down stream pressure loss (from the valve to devices), the PRV will re-open, allowing flow to pass through the valve until the pressure again reaches the valve set-point.

Pressure Reducing Valve Model No. Inlet Pressure*

The graph shows the repeat range based on set pressure

Set Pressure Range Repeatability A

Manifold Mount Valve Assembly

5000

70-5410-10 5,000 psi

750 to 4,500 psi 150 to 900 psi 300 to 900 psi

± 7%

5.6

< 3,000 psi >3,000 psi

4000

70-5410-01

± 10%

6.4

*Maximum Inlet Pressure for PRV is 5,000 psi. NOTE: Maximum system flow rate is 1.5 gpm

3000

For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 µ in. R a surface finish.

2000

(346.5 cu. in. per minute) for all VektorFlo ® special function valves, unless noted.

1000

Excess flow voids warranty.

0

Filter Plate For above Valves

0 1000 2000 3000 4000 5000 Set Pressure (PSI)

Order a Filter Plate to protect valves from debris. (More details end of section)

 70-5410-10 70-5437-70

 70-5410-01 70-5437-71

Model No. 70-8420-02

ILS705406 REV D

M-13

The graphs show the pressure drop through a PRV and manifold mount block

Pressure Adjustment Screw

Locknut

VEKTEK LP & HP PRV PRESSURE DROP VS FLOW

1.12 HEX

SAE 2 High Pressure Port (Inlet)

2.25 1.25

1.19

Manifold Mount O-rings Provided

Pressure Drop vs Flow

100 150 200 250 300 350 400 450 500

3X .28 THRU

A

.25

2X .77

1.50

2X 1.46

1.88

2X .25

2.12

2X .63

.50

SAE 4 Reduced Pressure Port (Outlet)

.50 2.00

1.25

.94

0 50

2.50

SAE 4 Port for Optional Gauge in Reduced Pressure Circuit

SAE 4 High Pressure Port (Inlet)

SAE 2 Reduced Pressure Port (Outlet)

0 0.5 1 1.5 2 2.53

ILS705405 REV F Flow (gpm)

ILS705407 REV C

© Vektek, January 2023

800-992-0236

www.vektek.com

Made with FlippingBook - Online magazine maker