Vektek Inch Hydraulic Clamping Catalog

Accessory Valves

Sequence Valve

DON’T DON’T

Sequence Valve  Control the timing of fixture devices.  Specialized construction resists corrosion which can cause other styles to “misfire.”  Direct acting poppet style construction.  Manifold mountable.  Cartridge may be installed directly into your manifold.  Two-port design eliminates need for third fluid line to drain bypass flow (internal leakage) back to system reservoir.  True sequence design allows full system pressure downstream of valve after opening. n Recommended Filtration: 25 Micron (NOM) / 40 Micron (ABS) (minimum).

DO DO

Sequence Valve Model No.

Set Pressure Range

Max Flow Rate

Filter Plate For above Valves Model No. 70-8420-03

A B

Order a Filter Plate to protect valve from debris. (More details end of section)

70-4400-01 300 to 900 psi 4.7 2.37 3.0 gpm 70-4400-02 750 to 5,000 psi 4.1 1.75 1.5 gpm *Maximum Inlet Pressure for sequence valve is 5,000 psi.

1.25

Adjustment Screw

Lock Nut

2X .93 Hex

L-10

B

SAE 2 Outlet Port*

SAE 4

Inlet Port

2X .52

.180

A

SAE 4 Outlet Port

M-10

3X 1.28

1.500

2.00

SAE 2 Inlet Port*

2X .56

1.00

1.250

.63

1.31

SAE 4 Inlet Port

2.50

1.25

2X .281 THRU

ILS704400 REV Q

NOTE: When using multiple sequence valves. For pressure set range 300 to 900 psi

*SAE 2 Ports are counterbored for o-rings that are used in manifold mounting applications. .09/ .15 FEED HOLES Excess flow voids warranty.

For proper sealing, mating surface should be flat to 0.003 in. with a maximum 63 R a µin. surface finish. a 100 psi spread between pressures is recommended. For pressure set range 750 to 5000 psi a 500 psi spread between pressures is recommended.

© Vektek, July 2024

800-992-0236

www.vektek.com

Made with FlippingBook - Online magazine maker