Vektek Inch Hydraulic Clamping Catalog

Accessory Valves

Sequence Cartridge

Adjustment Screw Lock Nut

2x .94 Hex

Sequence Valve Cartridge Model No. Set Pressure Range A B

Max Flow

B

70-4430-01 300 to 900 psi 3.8 2.37 3.0 gpm 70-4430-02 750 to 5,000 psi 3.2 1.75 1.5 gpm * Maximum Inlet Pressure for sequence valve is 5,000 psi, excess voids warranty.

A

M20 x 1.5 Thread

1.09

ILS704401 REV F

Sequence Valve Cartridge Cavity

30 5

.004 A

1.193 .010

.002 A .842 .004

.002 A Minor .734 .005

.010 .005

Thread M20 X 1.5 .44 Min. .002 A

4.37

63

4.00

.004 A

.118 .005

.650 .367 MIN MAX

45 5

.656 .005

1.199 MIN TOP OF HOLE DEPTH

L-12

.660 .005

.65

.75

1.25 .03

65-3002-02 STEP REAMER

65-3002-01 TAP M20 x 1.5

63

.203 .015 Sequence Outlet

1.375 MIN DEPTH

30 5

M-12

.592 .001

-A-

ILS704402 REV J

ANGLE OF INLET AND OUTLET HOLES CAN VARY AS LONG AS THE HOLE ENTERING THE CAVITY LIES BETWEEN THE MIN AND MAX DIMENSIONS SPECIFIED

.203 .015 Pressure Inlet

.500 .010

Multi-Step Carbide Cavity Contour Tool with Tap Kit Model No. 62-7040-00 Reamer and M20 x 1.5 tap

NOTE: If a sequence valve is no longer needed, use 30-6011-20 plug,

to cap cavity for free fluid pass through.

© Vektek, July 2024

800-992-0236

www.vektek.com

Made with FlippingBook - Online magazine maker