Accessory Valves
Pressure Reducing Valve
Pressure Reducing Valve Control pressure to individual devices. For use in double or single acting systems. Direct acting, poppet style, adjustable, cartridge construction. Cartridge may be installed directly into your manifold.
Model 70-5410-10 set the pressure range from 750 to 4500 psi. Repeatability ± 7% Model 70-5410-01 set the pressure range from 150 to 900 psi. Repeatability ± 10% Maximum inlet pressure 5,000 psi. Pressure Reducing Cartridge is interchangeable with the Pressure Limiting Cartridge in the same mounting cavity. Two-port design eliminates need for third fluid line to drain bypass flow (internal leakage) back to system reservoir. n Recommended Filtration: 25 Micron (NOM) /40 Micron (ABS) (minimum). Operation: The Pressure Reducing Valve (PRV) is a Normally Open (N/O) pressure control device. The valve remains open and fluid flows freely to downstream devices (from the valve to devices) until the pressure in the valve reaches the pressure (adjustable) set-point. At the set-point pressure, the valve closes blocking further flow and pressure rise to the downstream devices. If there is a sufficient down stream pressure loss (from the valve to devices), the PRV will re-open, allowing flow to pass through the valve until the pressure again reaches the valve set-point.
Pressure Reducing Valve Model No. Inlet Pressure*
The graph shows the repeat range based on set pressure
Set Pressure Range Repeatability A
Manifold Mount Valve Assembly
5000
70-5410-10 5,000 psi
750 to 4,500 psi 150 to 900 psi 300 to 900 psi
± 7%
5.6
< 3,000 psi >3,000 psi
4000
70-5410-01
± 10%
6.4
*Maximum Inlet Pressure for PRV is 5,000 psi. ** SAE 2 Ports are counterbored for O-Rings that are used in manifold mounting applications. 0.09/0.15 dia feed holes. NOTE: Maximum system flow rate is 1.5 gpm
3000
2000
For proper sealing, mating surface must be flat within 0.003 in. with a maximum 63 µ in. R a surface finish.
(346.5 cu. in. per minute) for all VektorFlo ® special function valves, unless noted.
1000
0
Excess flow voids warranty.
0 1000 2000 3000 4000 5000 Set Pressure (PSI)
L-14
Filter Plate For above Valves
Order a Filter Plate to protect valves from debris. (More details end of section)
70-5410-10 70-5437-70
70-5410-01 70-5437-71
Model No. 70-8420-02
ILS705406 REV D
M-14
The graphs show the pressure drop through a PRV and manifold mount block
Pressure Adjustment Screw
Locknut
VEKTEK LP & HP PRV PRESSURE DROP VS FLOW
1.12 HEX
SAE 2 High Pressure Port (Inlet)
2.25 1.25
Pressure Drop vs Flow
1.19
Manifold Mount O-rings Provided
100 150 200 250 300 350 400 450 500
3X .28 THRU
A
.25
2X .77
1.50
2X 1.46
1.88
2X .25
2.12
2X .63
.50
SAE 4 Reduced Pressure Port (Outlet)
.50 2.00
0 50
1.25
.94
2.50
SAE 4 Port for Optional Gauge in Reduced Pressure Circuit
SAE 4 High Pressure Port (Inlet)
0 0.5 1 1.5 2 2.53
**SAE 2 Reduced Pressure Port (Outlet)
ILS705405 REV F Flow (gpm)
ILS705407 REV D
© Vektek, July 2024
800-992-0236
www.vektek.com