Vektek Inch Hydraulic Clamping Catalog

Accessory Valves

Sequence Cartridge

Adjustment Screw Lock Nut

2x .94 Hex

Sequence Valve Cartridge Model No. Set Pressure Range A B

Max Flow

B

70-4430-01 300 to 900 psi 3.8 2.37 3.0 gpm 70-4430-02 750 to 5,000 psi 3.2 1.75 1.5 gpm * Maximum Inlet Pressure for sequence valve is 5,000 psi, excess voids warranty.

A

M20 x 1.5 Thread

1.09

ILS704401 REV F

Sequence Valve Cartridge Cavity

30 5

.004 A

1.193 .010

.002 A .842 .004

.002 A Minor .734 .005

.010 .005

Thread M20 X 1.5 .44 Min. .002 A

4.37

63

4.00

.004 A

.118 .005

.650 .367 MIN MAX

45 5

.656 .005

1.199 MIN TOP OF HOLE DEPTH

.660 .005

.65

.75

1.25 .03

65-3002-02 STEP REAMER

65-3002-01 TAP M20 x 1.5

63

.203 .015 Sequence Outlet

1.375 MIN DEPTH

30 5

.592 .001

-A-

ILS704402 REV J

ANGLE OF INLET AND OUTLET HOLES CAN VARY AS LONG AS THE HOLE ENTERING THE CAVITY LIES BETWEEN THE MIN AND MAX DIMENSIONS SPECIFIED

.203 .015 Pressure Inlet

L-12

.500 .010

Multi-Step Carbide Cavity Contour Tool with Tap Kit Model No. 62-7040-00 Reamer and M20 x 1.5 tap

P-12

NOTE: If a sequence valve is no longer needed, use 30-6011-20 plug,

to cap cavity for free fluid pass through.

© Vektek, August 2026

800-992-0236

www.vektek.com

Made with FlippingBook - Online magazine maker