Work Supports
Legacy Fluid Advance Cartridges
Cavity Check List √ Confirm capacity of item selected.
B-31
Note the sealing surface finish requirements. Minimum depth specification represents the
nominal depth of the standard Vektek base dimension. Confirm cavity drawing is appropriate for the model number used. Note specified thread depth when cutting threads. When using a bottoming tap tool, modifications may be required. When hand tapping threads, perpendicularity is essential.
B
M
C STROKE
A THREAD
G HEX
J
V HEX x W THREAD
H
E
F
D
GASKET, ON MODELS 10-0706-04, 10-0706-14, 10-0708-07, AND 10-0708-17 ONLY, WILL COMPRESS TO APPROXIMATELY .020 THICK WHEN INSTALLED.
ILS100702 REV N
Cartridge Dimensions Model No.
A B C D E F G H J
M V
W
10-0706-04 10-0706-14 10-0708-07 10-0708-17
2.12 0.25 1.68 2.62 0.50 2.18 2.83 0.25 2.17
5/16-18 X 0.20 3/8-24 X 0.20
1-16
0.24 0.21 0.88 0.62 0.14 0.92 0.50
1 1/4-16
0.31 0.36 1.13 0.81 0.19 1.17 0.63 7/16-14 X 0.25
3.33 0.50 2.67 10-0715-06 2 1/4-16 2.85 0.50 2.16 0.19 0.50 2.00 1.50 0.19 2.16 0.75 1/2-13 X 0.25
© Vektek, July 2024
800-992-0236
www.vektek.com