Vektek Inch Hydraulic Clamping Catalog

Swing Clamps and Arms

Bottom Flange Long Stroke

SAE 2 PORT TOP & BOTTOM UNCLAMP FOR MANIFOLD MOUNTING

Q V

ORDER ARM SEPARATELY

AC UNCLAMP PORT

N TOTAL STROKE M CLAMP STROKE

6x AD x 90 ARM CLOCKING FEATURE

J PLUNGER THREAD

2x X

P

C-12

5x K***

H .156 .005

6x L 2x G

A

4x Y

4x R

AC CLAMP OR FLOW CONTROL PORT

F

T

D

SAE 2 PORT TOP & BOTTOM CLAMP FOR MANIFOLD MOUNTING

E

C

B

ILS142007 REV M

SWING CLAMP PLUNGER SHOWN IN THE EXTENDED LH CAM POSITION

For proper sealing, mating surface must be flat within 0.003 in with a maximum 63 µ in. R a surface finish.

DRAWING NOTES: * All models are shipped with removable steel plugs installed. O-Ring face seals provided. *** All five mounting screws must be used when manifold mounting, to assure a leak-free O-Ring seal.

Chamfer Fixture Hole 45 X .015 Max.

Optional top or bottom o-ring face seal mounting configuration.

A .010 Fixture Hole

4X Thread B

.09-.15 Feeder hole

4X C .005

Port Plug

Fixture Plate

G .005

2X E .010

.09-.15 Feeder hole

2X F .010

D .005

.110 .020 Clamp

ILS142008 REV C

.110 .020 Unclamp/ Vent Feed Hole For Manifold Mounting

Feed Hole For Manifold Mounting

Model No.

M

Double Acting 14-2209-10-L 14-2209-10-R 14-2209-10-S 14-2213-10-L 14-2213-10-R 14-2213-10-S

Mounting Dimensions ModelNo.A B C D E F G 14-2209-10-X 1.515 1/4-20 0.562 0.812 1.125 0.562 0.988 14-2213-10-X 1.890 5/16-18 0.688 1.000 1.250 0.750 1.214

0.75 0.75 1.21 1.34 1.34 2.00

K

L

N P

Q R

T

V

X

Y

AC AD

0.28 0.34

0.56 0.75

1.21 2.00 0.99 2.00 2.50 1.21

0.56 0.69

2.41 2.72

0.75 0.81 1.13 0.94 1.00 1.25

SAE 4 SAE 4

0.19 0.19

www.vektek.com

800-992-0236

© Vektek, July 2024

Made with FlippingBook - Online magazine maker