Swing Clamps and Arms
Bottom Flange Long Stroke
SAE 2 PORT TOP & BOTTOM UNCLAMP FOR MANIFOLD MOUNTING
Q V
ORDER ARM SEPARATELY
AC UNCLAMP PORT
N TOTAL STROKE M CLAMP STROKE
6x AD x 90 ARM CLOCKING FEATURE
J PLUNGER THREAD
2x X
P
C-12
5x K***
H .156 .005
6x L 2x G
A
4x Y
4x R
AC CLAMP OR FLOW CONTROL PORT
F
T
D
SAE 2 PORT TOP & BOTTOM CLAMP FOR MANIFOLD MOUNTING
E
C
B
ILS142007 REV M
SWING CLAMP PLUNGER SHOWN IN THE EXTENDED LH CAM POSITION
For proper sealing, mating surface must be flat within 0.003 in with a maximum 63 µ in. R a surface finish.
DRAWING NOTES: * All models are shipped with removable steel plugs installed. O-Ring face seals provided. *** All five mounting screws must be used when manifold mounting, to assure a leak-free O-Ring seal.
Chamfer Fixture Hole 45 X .015 Max.
Optional top or bottom o-ring face seal mounting configuration.
A .010 Fixture Hole
4X Thread B
.09-.15 Feeder hole
4X C .005
Port Plug
Fixture Plate
G .005
2X E .010
.09-.15 Feeder hole
2X F .010
D .005
.110 .020 Clamp
ILS142008 REV C
.110 .020 Unclamp/ Vent Feed Hole For Manifold Mounting
Feed Hole For Manifold Mounting
Model No.
M
Double Acting 14-2209-10-L 14-2209-10-R 14-2209-10-S 14-2213-10-L 14-2213-10-R 14-2213-10-S
Mounting Dimensions ModelNo.A B C D E F G 14-2209-10-X 1.515 1/4-20 0.562 0.812 1.125 0.562 0.988 14-2213-10-X 1.890 5/16-18 0.688 1.000 1.250 0.750 1.214
0.75 0.75 1.21 1.34 1.34 2.00
K
L
N P
Q R
T
V
X
Y
AC AD
0.28 0.34
0.56 0.75
1.21 2.00 0.99 2.00 2.50 1.21
0.56 0.69
2.41 2.72
0.75 0.81 1.13 0.94 1.00 1.25
SAE 4 SAE 4
0.19 0.19
www.vektek.com
800-992-0236
© Vektek, July 2024
Made with FlippingBook - Online magazine maker