Vektek Inch Hydraulic Clamping Catalog

Swing Clamps and Arms

Low Profile Clamp Time and Flow Rates, Low Profile Clocking

TuffCam™ Clocking Features Three clocking features have been added to Vektek’s Low Profile Swing Clamp line. Customers have requested the clocking features to help improve and speed-up arm changes. A drill point on each clamp standardizes arm location at a particular position. An additional two orientation drill points reside 120° out from that position and each other. Access to the positioning feature is through the back or side of the arm, making modification a snap for users. Each arm position can have its own specification.

C-18

Set Screw

Reference this dimension according to your arm selection.

.420 .005 From Arm Crossbolt Location

Clamped Position

Straight Pull

90 Right Swing To Clamp

90 Left Swing To Clamp

Suggested location of drilled & tapped hole in the arm using a single acting assembly. Shown with standard arm. End user must add tapped hole to arm in proper location/orientation for their application.

2X 120

2X 120

3X Clocking Features Shown At Clamped Position

3X Clocking Features Shown At Clamped Position

ILS140024 REV D

TuffCam™ Low Profile Swing Clamp Arm Clocking Feature Views shown apply to double and single acting TuffCam™ Top Flange and Bottom Flange models. Three counter sunk Ø .19 x 90˚ Clocking Feature drill points are shown in the clamped position. The three (3) Clocking Features are equally spaced 120˚.

Clamp Time and Fluid Flow Rates for TuffCam™

CLAMP POSITION

Standard Arm

Extended Arm

Swing Clamp Capacity (lbs.)

30º

Maximum Permissible Flow Rate (cu. in./min. )

Fastest Allowable Clamp Time (sec.)

Maximum Permissible Flow Rate (cu. in./min.)

Fastest Allowable Clamp Time (sec.)

45º

60º

5000 7500

0.5 0.5

155 251

1.0 1.0

78

90º

126

NOTE: Arm Length and Pressure Limitation Graphs in end of section. The above flows are maximum recommendations and clamp times are minimum recommendations. - For upreach and double arms, use extended arm flows and times. - When using custom arms the extended arm flows and times are to be considered the limiting factor. - The actual time to position the clamp will vary by custom arm configuration and may require customer testing in specific application to establish limits.