Vektek Low Pressure 7MPa Catalog

7 MPa Work Supports

Fluid Advance Bottom Flange Work Support

Retracted Plunger Applications n Available in four capacities ranging from 3.0 kN to 10 kN.  Normally retracted plungers do not interfere with part loading. Advance them with hydraulic pressure, exerting only spring force to bring plunger into contact with the part. Hydraulic pressure then automatically sequences, “freezing” the plunger properly against the part. n Choose between a High-Tension or Low-Tension Spring to fit your application. n Plumb through BSPP ports or manifold mount. Optional flow control requires the use of manifold mount ports. n “Floating” locator that doesn't interfere with 3-2-1 locating principles. n Only spring force is applied to the part. Hydraulic actuation freezes the plunger without exerting any additional force on the part. n Minimal friction wiper design keeps chips and debris out while providing smooth plunger action. n In The Port flow control valves can be used to control the plunger advance rate on supports using manifold mount hydraulics. n Optional In The Port flow control is a meter-in device with reverse free flow check valve. n Optional In The Port sequence valve is a pressure sequencing device with reverse free flow check valve.

B-9

Shown with Optional In The Port

Precision Flow Control Valve

Bearing grade stainless steel plunger and collet assembly helps guard against corrosion in most machining environments.

Specifications

L1-0610-00-L L1-0610-00-H

L1-0612-00-L L1-0612-00-H

L1-0615-00-L L1-0615-00-H

L1-0616-00-L L1-0616-00-H

Model No.

Support Capacity* (kN) Support Capacity Formula** (kN)

3.0

4.0

5.5

10

(P-1) x 0.500 (P-1) x 0.667 (P-1) x 0.917 (P-1) x 1.667

Stroke*** (mm)

6.5

8

8

10

Contact Force - L (N) Contact Force - H (N)

3.7 - 6.1

4.3 - 7.4

9.2 -13.7 9.3 -14.7

6.2 - 9.0 8.8 - 14.9 12.8 - 20.7 12.7 - 22.8

Oil Capacity (cm 3 )

0.55

0.80

1.02

1.49

Port X Depth for Optional In The Port Valves****

G 1/8 X 15.16

Fluid Advance Work Support, hydraulic pressure pushes a spring which lifts plunger; hydraulic pressure locks in place.

ILML10600 REV F

WARNING: Operating above 7 MPa may damage the work support and will void warranty. * Support capacities are listed at 7 MPa (70 bar) maximum pressure. Support capacities for other pressures are shown on the Capacity Charts at the start of Section B. Operating work supports above maximum pressure may damage work support and void warranty. ** "P" in the formula is hydraulic pressure measured in MPa. *** To allow for work piece height variations, it is recommended that the plunger contacts the part at Mid-Stroke.

**** Set plunger lifting time to 0.5 seconds, or longer, by adjusting the flow control valve. Use a flow control valve with cracking pressure of 0.1 MPa or less. In The Port valves require the use of manifold mount ports.

NOTE: Work Support Capacity to be equal to or greater than 1.5 times clamping force plus machining force.

NOTE: The maximum system back-pressure a fluid advance work support can overcome is 0.07 MPa (0.7 bar). Return back-pressure greater than 0.07 MPa (0.7 bar) may cause slow or failed retraction.

© Vektek February 2021

1-800-992-0236

www.vektek.com

Made with FlippingBook - professional solution for displaying marketing and sales documents online