TuffCam ™ 7 MPa Swing Clamp Arms
Clamping Force Tables
L1-4X32-00
L1-4X25-00
Max Arm Length “L” (mm)
Max Arm Length “L” (mm)
Clamping Force (kN) Arm Length “L” (mm)
Clamping Force (kN) Arm Length “L” (mm)
Operating Pressure (MPa)
Cylinder Force (kN)
Operating Pressure (MPa)
Cylinder Force (kN)
30 45.5 60 75
86 100 120 150
30 40
49
60 80
98 120 150
10.0
3.1 2.7 2.4 2.1 1.9 1.8 1.7 1.5
143
10.0
5.5 5.1 4.8 4.5 4.2 3.9
92
9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0
2.8 2.5 2.1 1.9 1.7 1.6 1.5 1.4 1.2 150 2.5 2.2 1.9 1.7 1.6 1.5 1.4 1.2 1.1 150 2.2 1.9 1.7 1.5 1.4 1.3 1.2 1.1 0.9 150 1.9 1.6 1.4 1.3 1.2 1.1 1.0 0.9 0.8 150 1.6 1.4 1.2 1.1 1.0 0.9 0.8 0.8 0.7 150 1.3 1.1 0.9 0.9 0.8 0.7 0.7 0.6 0.5 150 0.9 0.8 0.7 0.6 0.6 0.5 0.5 0.5 0.4 150 0.6 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.3 150 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.1 150
9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0
4.9 4.6 4.3 4.1 3.8 3.5 3.3 4.4 4.1 3.8 3.6 3.4 3.1 2.9 2.7
109 132
3.8 3.6 3.3 3.2 3.0 2.7 2.5 2.3 2.1 150 3.3 3.1 2.9 2.7 2.5 2.3 2.2 2.0 1.8 150 2.7 2.6 2.4 2.3 2.1 1.9 1.8 1.7 1.5 150 2.2 2.1 1.9 1.8 1.7 1.6 1.4 1.3 1.2 150 1.6 1.5 1.4 1.4 1.3 1.2 1.1 1.0 0.9 150 1.1 1.0 1.0 0.9 0.8 0.8 0.7 0.7 0.6 150 0.5 0.5 0.5 0.5 0.4 0.4 0.4 0.3 0.3 150
Max Op. Pressure (MPa)
Max Op. Pressure (MPa)
10.0 10.0 10.0 10.0 10.0 10.0 10.0 9.8
10.0 10.0 10.0 10.0 10.0 9.6 8.4 7.4
D-4
ILML.14007-25 REV B
ILML14007-32 REV B
L1-4X40-00
L1-4X50-00
Clamping Force (kN) Arm Length “L” (mm)
Clamping Force (kN)
Max Arm Length “L” (mm)
Max Arm Length “L” (mm)
Operating Pressure (MPa)
Cylinder Force (kN)
Operating Pressure (MPa)
Cylinder Force (kN)
Arm Length “L” (mm) 35 45 58.5 70 90 110 155 200
42 55
68
90 115 142 170 200
10.0
8.8 8.3 7.8 7.3 7.0 6.5 7.9 7.5 7.1 6.6 6.3 5.8 5.5 7.0 6.7 6.3 5.9 5.6 5.2 4.9 6.1 5.8 5.5 5.1 4.9 4.5 4.3 3.8
97
10.0
13.5 12.2 11.4 10.8 9.9 9.2 8.6 12.1 11.0 10.3 9.7 8.9 8.3 7.7 7.2
156 186
9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0
114 137 170
9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0
10.8 9.8 9.1 8.6 8.0 7.4 6.9 6.4 6.0 200 9.4 8.6 8.0 7.6 7.0 6.4 6.0 5.6 5.3 200 8.1 7.3 6.9 6.5 6.0 5.5 5.1 4.8 4.5 200 6.7 6.1 5.7 5.4 5.0 4.6 4.3 4.0 3.8 200 5.4 4.9 4.6 4.3 4.0 3.7 3.4 3.2 3.0 200 4.0 3.7 3.4 3.2 3.0 2.8 2.6 2.4 2.3 200 2.7 2.4 2.3 2.2 2.0 1.8 1.7 1.6 1.5 200 1.3 1.2 1.1 1.1 1.0 0.9 0.9 0.8 0.8
5.3 5.0 4.7 4.4 4.2 3.9 3.7 3.3 3.0 200 4.4 4.2 3.9 3.7 3.5 3.2 3.0 2.7 2.5 200 3.5 3.3 3.1 2.9 2.8 2.6 2.4 2.2 2.0 200 2.6 2.5 2.4 2.2 2.1 1.9 1.8 1.6 1.5 200 1.8 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0 200 0.9 0.8 0.8 0.7 0.7 0.6 0.6 0.5 0.5 200
Max Op. Pressure (MPa)
Max Op. Pressure (MPa)
10.0 10.0 10.0 10.0 10.0 9.2 7.4 6.3
10.0 10.0 10.0 10.0 10.0 10.0 9.5 8.6
ILML14007-40 REV B
ILML14007-50 REV B
L1-4X63-00
L1-4X80-00
Clamping Force (kN)
Max Arm Length “L” (mm)
Clamping Force (kN)
Max Arm Length “L” (mm)
Operating Pressure (MPa)
Cylinder Force (kN)
Operating Pressure (MPa)
Cylinder Force (kN)
Arm Length “L” (mm) 50 65 80.5 110 140 176 210 250
Arm Length “L” (mm) 60 89.5 120 150 180 220 260 300 31.3 28.7 26.8 25.4 24.2 22.9 28.2 25.9 24.1 22.9 21.8 20.6 19.7
10.0
34.4 30.9 27.5 24.1 20.6 17.2 13.7 10.3
243 284
10.0
21.0 19.1 18.0 17.2 15.9 15.0 14.1 18.9 17.2 16.2 15.5 14.3 13.5 12.7 12.0
200 233
9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0
9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0
25.0 23.0 21.5 20.3 19.4 18.3 17.5 16.7 300 21.9 20.1 18.8 17.8 16.9 16.0 15.3 14.6 300 18.8 17.2 16.1 15.2 14.5 13.7 13.1 12.5 300 15.7 14.4 13.4 12.7 12.1 11.5 10.9 10.5 300 12.5 11.5 10.7 10.2 9.7 9.2 8.7 8.4 300 9.4 8.6 8.0 7.6 7.3 6.9 6.6 6.3 300 6.3 5.7 5.4 5.1 4.8 4.6 4.4 4.2 300 3.1 2.9 2.7 2.5 2.4 2.3 2.2 2.1
16.8 15.2 14.4 13.7 12.7 12.0 11.3 10.7 10.1 250 14.7 13.3 12.6 12.0 11.1 10.5 9.8 9.4 8.9 250 12.6 11.4 10.8 10.3 9.6 9.0 8.4 8.0 7.6 250 10.5 9.5 9.0 8.6 8.0 7.5 7.0 6.7 6.3 250 8.4 7.6 7.2 6.9 6.4 6.0 5.6 5.3 5.1 250 6.3 5.7 5.4 5.2 4.8 4.5 4.2 4.0 3.8 250 4.2 3.8 3.6 3.4 3.2 3.0 2.8 2.7 2.5 250 2.1 1.9 1.8 1.7 1.6 1.5 1.4 1.3 1.3
6.9 3.4
Max Op. Pressure (MPa)
Max Op. Pressure (MPa)
10.0 10.0 10.0 10.0 10.0 10.0 9.6 8.6
10.0 10.0 10.0 10.0 10.0 10.0 9.5 8.6
ILML14007-63 REV B
ILML14007-80 REV B
How to Use the Clamping Force Tables 1) Start by choosing the arm length you need for your application. 2) Then move along the line and select the clamping force and operating pressure or operating pressure and clamping force needed. Example: Using a L1-4X25-00 with a 30 mm arm; the clamping force would be 1.4 kN at 5.0 MPa L1-4X25-00 Operating Pressure (MPa) Cylinder Force (kN) Clamping Force (kN) Arm Length “L” (mm)
= Non-Usable Range
• The tables and graphs show the relationship between arm length, operating pressure and clamping force. • The arm lengths shown in parentheses (page D-5) are the usable length from
the edge of the clamp body to the contact bolt. • Tables include maximum operating pressure associated with the arm length shown in the header rows of the table. • The column on the right of the table is the maximum arm length allowed at the associated operating pressure. • Operating the clamp in the
Max Arm Length “L” (mm)
30 45.5 60 75
86 100 120 150
10.0
3.1 2.7 2.4 2.1 1.9 1.8 1.7 1.5
143
9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0
2.8 2.5 2.1 1.9 1.7 1.6 1.5 1.4 1.2 150 2.5 2.2 1.9 1.7 1.6 1.5 1.4 1.2 1.1 150 2.2 1.9 1.7 1.5 1.4 1.3 1.2 1.1 0.9 150 1.9 1.6 1.4 1.3 1.2 1.1 1.0 0.9 0.8 150 1.6 1.4 1.2 1.1 1.0 0.9 0.8 0.8 0.7 150 1.3 1.1 0.9 0.9 0.8 0.7 0.7 0.6 0.5 150 0.9 0.8 0.7 0.6 0.6 0.5 0.5 0.5 0.4 150 0.6 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.3 150 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.1 150
non-usable range will damage the clamp and void product warranty.
USABLE LENGTH
Max Op. Pressure (MPa)
10.0 10.0 10.0 10.0 10.0 10.0 10.0 9.8
ILML14008 REV B