7 MPa Link Clamps
Link Clamp Dimensions
* PLUGS INSTALLED STANDARD LEVER SHOWN
X
S TOTAL STROKE
3 CLAMP ANGLE
R CLAMP STROKE
Dimensions Model No. L1-6025-00 L1-6032-00 L1-6040-00 L1-6050-00 L1-6063-00 Double Acting (D/A) Cylinders, actuated hydraulically both directions. A 76.7 86.0 100.2 119.1 138.5 B 42 50 62 75 90 C 56 61 72 87.5 101 D 27 27 29 34 36 E 28.23 31.98 37.88 43.73 52.38 F 21 25 31 37.5 45 G 21 25 31 37.5 45 H 20 18 17 20 20 J 4.8 5.8 6.8 8.8 10.8 K 8.25 9.75 11.25 14.5 17.25 L 13 13 13 15 15 M 10 11 14 16 18 N G 1/8 G 1/8 G 1/8 G 1/4 G 1/4 Q 12 15 18 22 26 R 16.5 19.75 24.4 29.5 35.1 S 19.5 23.25 28.15 34 40.1 T 46.5 50 57 67.5 75.5 V 60.5 68 77 92.5 105.5 W 80.6 93.2 105.8 127.8 142.1 X 19 18 19 19 20 Y 50 62 72 88 100 Z 35 41.5 51 59 72 AA 51.5 56 65 77.5 87.5 AB 33 34 37.5 44.5 48 AC 21.5 27 30.5 37 44.5 MA 36 43 54 65 78 MB 16.5 20 25 30 36.5 MC 16.5 20 25 30 36.5 MD M4 M5 M6 M8 M10 ME 26.5 28 33 40 46 MF 10 11 14 16 18 MG 3 3 3 6 6 ILML16001 REV D
Y
W A
AC
V
Q
AA
T
H
AB
D
L 2X
E
E-3
-0.1 -0.36
MA
CLAMP MANIFOLD PORT* N CLAMP PORT*
4X J THRU K
Z
MB
M 2X
MC
B
N UNCLAMP PORT*
F
MF 2X
G
ME 2X
UNCLAMP MANIFOLD PORT*
C
MB 0.13 4X
+0.26 -0
MA
MG MAX
MD 4X
CLAMP FEED HOLE
MF 0.25 2X
MC 0.13 4X
CHAMFER 0.5 X 45
MG MAX UNCLAMP FEED HOLE
ME 0.25 2X
ILML16001 REV D
Plumbing Options
Plumbed through the fixture using manifold mount port
Plumbed through tubing using G port
For proper sealing, the mating surface must be flat within 0.08 mm with a maximum surface roughness of 1.6 µm R a