7 MPa Link Clamp Levers
Clamping Force Tables
L1-6025-00
L1-6032-00
Min Lever Length “L” (mm)
Min Lever Length “L” (mm)
Operating Pressure (MPa)
Cylinder Force (kN)
Operating Pressure (MPa)
Cylinder Force (kN)
Clamping Force (kN)
Clamping Force (kN)
Lever Length “L” (mm)
Lever Length “L” (mm)
24
35
40 46.5 50
61
80 100
29 35 41.5 50.5 60
72 100 120
10.0 4.9
1.0 0.8 74
10.0 8.0
1.6 1.3 90
9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0
4.4 3.9 3.4 2.9 2.5
1.3 0.9 0.7 55
9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0
7.2 6.4 5.6 4.8 4.0
2.2 1.5 1.2 62
1.7 1.5 1.2 0.8 0.6 42 2.4 1.9 1.5 1.4 1.0 0.7 0.6 34 2.0 1.6 1.3 1.2 0.9 0.6 0.5 29 1.7 1.4 1.1 1.0 0.7 0.5 0.4 25
3.3 2.5 2.0 1.3 1.0 49 4.0 2.9 2.2 1.7 1.1 0.9 40 4.7 3.4 2.5 1.9 1.5 1.0 0.8 34 3.9 2.8 2.0 1.6 1.2 0.8 0.7 30
2.0 3.0 1.4 1.1 0.9 0.8 0.6 0.4 0.3 24 1.5 2.3 1.0 0.8 0.6 0.6 0.4 0.3 0.2 24 1.0 1.5 0.7 0.5 0.4 0.4 0.3 0.2 0.2 24 0.5 0.8 0.3 0.3 0.2 0.2 0.1 0.1 0.1 24
3.2 4.8 3.1 2.3 1.6 1.3 1.0 0.6 0.5 29 2.4 3.6 2.4 1.7 1.2 1.0 0.7 0.5 0.4 29 1.6 2.4 1.6 1.1 0.8 0.6 0.5 0.3 0.3 29 0.8 1.2 0.8 0.6 0.4 0.3 0.2 0.2 0.1 29
Max Op. Pressure (MPa)
Max Op. Pressure (MPa)
4.8 7.2 7.9 8.5 8.7 9.3 10.0 10.0
4.9 6.2 7.2 8.1 8.8 9.4 10.0 10.0
ILML16005-25 REV B
ILML16005-32 REV C
L1-6040-00
L1-6050-00
Min Lever Length “L” (mm)
Min Lever Length “L” (mm)
Clamping Force (kN)
Operating Pressure (MPa)
Cylinder Force (kN)
Clamping Force (kN)
Operating Pressure (MPa)
Cylinder Force (kN)
Lever Length “L” (mm)
Lever Length “L” (mm)
F-2
43.5 50
59 70.5 90 102.5 130 150
36 42
51 61.5 80
89 120 140
10.0 19.6 9.0 17.7 8.0 15.7 7.0 13.7
4.6 3.9 116
10.0 12.6 9.0 11.3 8.0 10.1
2.6 2.2 109
6.8 5.0 4.2 3.5 86 8.7 6.0 4.4 3.7 3.1 68 10.3 7.6 5.3 3.9 3.2 2.7 57
3.9 3.4 2.3 1.9 78 5.2 3.5 3.0 2.1 1.7 60 6.1 4.5 3.1 2.7 1.8 1.5 49 7.6 5.3 3.9 2.6 2.3 1.6 1.3 42
7.0 6.0 5.0 4.0 3.0 2.0 1.0
8.8 7.5
6.0 11.8 12.2 8.8 6.5 4.5 3.3 2.8 2.3 49 5.0 9.8 14.1 10.2 7.4 5.4 3.8 2.8 2.3 1.9 43.5 4.0 7.9 11.3 8.1 5.9 4.4 3.0 2.2 1.9 1.6 43.5 3.0 5.9 8.4 6.1 4.4 3.3 2.3 1.7 1.4 1.2 43.5 2.0 3.9 5.6 4.1 2.9 2.2 1.5 1.1 0.9 0.8 43.5 1.0 2.0 2.8 2.0 1.5 1.1 0.8 0.6 0.5 0.4 43.5 Max Op. Pressure (MPa) 5.2 6.2 7.2 8.1 9.1 9.6 10.0 10.0 ILML16005-50 REV C
6.3 9.1 6.4 4.4 3.2 2.2 1.9 1.3 1.1 36 5.0 7.3 5.1 3.5 2.6 1.8 1.5 1.0 0.9 36 3.8 5.5 3.8 2.6 1.9 1.3 1.1 0.8 0.6 36 2.5 3.6 2.5 1.8 1.3 0.9 0.8 0.5 0.4 36 1.3 1.8 1.3 0.9 0.6 0.4 0.4 0.3 0.2 36
Max Op. Pressure (MPa)
5.0 6.1 7.2 8.1 9.1 9.4 10.0 10.0
ILML16005-40 REV C
L1-6063-00
Indicates Non-Usable Range
Min Lever Length “L” (mm)
Clamping Force (kN)
Operating Pressure (MPa)
Cylinder Force (kN)
Lever Length “L” (mm)
53 60
72 83 100 125 140 160
Minimum Lever Length Using lever shorter than minimum lever length will produce large clamping forces leading to premature failure of link plates or pins.
10.0 31.2 9.0 28.1 8.0 24.9 7.0 21.8
7.2 145
9.4 7.9 6.5 106 10.8 8.3 7.1 5.7 84
16.1 12.6 9.4 7.3 6.2 5.0 69
6.0 18.7 19.7 13.8 10.8 8.1 6.3 5.3 4.3 59 5.0 15.6 21.9 16.4 11.5 9.0 6.7 5.2 4.4 3.6 53 4.0 12.5 17.5 13.1 9.2 7.2 5.4 4.2 3.5 2.9 53 3.0 9.4 13.1 9.8 6.9 5.4 4.0 3.1 2.6 2.2 53 2.0 6.2 8.7 6.6 4.6 3.6 2.7 2.1 1.8 1.4 53 1.0 3.1 4.4 3.3 2.3 1.8 1.3 1.0 0.9 0.7 53 Max Op. Pressure (MPa) 5.2 6.1 7.2 7.9 8.7 9.5 9.9 10.0 ILML16005-63 REV C
L1-6025-00
Min Lever Length “L” (mm)
Operating Pressure (MPa)
Cylinder Force (kN)
Clamping Force (kN)
How to Use the Clamping Force Tables 1) Start by choosing the lever length you need for your application. 2) Then move along the line and select the clamping force and operating pressure or operating pressure and clamping force needed. Example: Using a L1-6025-00 with a 35 mm lever; the clamping force would be 2.0 kN at 6.0 MPa
Lever Length “L” (mm) 24 35 40 46.5 50 61 80 100
10.0 4.9
1.0 0.8 74
9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0
4.4 3.9 3.4 2.9 2.5
1.3 0.9 0.7 55
1.7 1.5 1.2 0.8 0.6 42 2.4 1.9 1.5 1.4 1.0 0.7 0.6 34 2.0 1.6 1.3 1.2 0.9 0.6 0.5 29 1.7 1.4 1.1 1.0 0.7 0.5 0.4 25
2.0 3.0 1.4 1.1 0.9 0.8 0.6 0.4 0.3 24 1.5 2.3 1.0 0.8 0.6 0.6 0.4 0.3 0.2 24 1.0 1.5 0.7 0.5 0.4 0.4 0.3 0.2 0.2 24 0.5 0.8 0.3 0.3 0.2 0.2 0.1 0.1 0.1 24
Max Op. Pressure (MPa)
4.8 7.2 7.9 8.5 8.7 9.3 10.0 10.0
ILML16006 REV A
© Vektek February 2021
1-800-992-0236
www.vektek.com
Made with FlippingBook - professional solution for displaying marketing and sales documents online