Vektek Low Pressure 7MPa Catalog

7 MPa Link Clamp Levers

Clamping Force Graphs

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 012345678910 Operating Pressure (MPa) L1-6032-00 (32mm Bore) L = 29 (4) L = 35 (10)

L1-6025-00 (25mm Bore)

Non-Usable Range

Non-Usable Range

3.5

L = 24 (3)

L = 41.5 (16.5)

3.0

L = 35 (14) L = 40 (19)

2.5

L= 50.5 (25.5)

L = 46.5 (25.5)

2.0

L= 72 (47) L = 60 (35) L = 100 (75) L = 120 (95)

L = 50 (29)

1.5

L = 61 (40) L = 80 (59)

1.0

L = 100 (79)

0.5

0.0

0 1 2 3 4 5 6 7 8 Operating Pressure (MPa)

10

ILML16005-32 REV C

ILML16005-25 REV B

L1-6050-00 (50mm Bore)

0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 012345678910 Operating Pressure (MPa) L1-6040-00 (40mm Bore) L = 36 (5) L = 42 (11)

Non-Usable Range

Non-Usable Range

14.0

L = 43.5 (6)

F-3

12.0

L = 59 (21.5)

L = 51 (20)

L = 50 (12.5)

10.0

L = 70.5 (33)

L = 61.5 (30.5)

8.0

L = 90 (52.5)

L = 80 (49)

6.0

L =102.5 (65) L = 130 (92.5) L = 150 (112.5)

L = 120 (89) L = 89 (58) L = 140 (109)

4.0

2.0

0.0

012345678910 Operating Pressure (MPa)

ILML16005-50 REV C

ILML16005-40 REV C

• The tables and graphs show the relationship between lever length, operating pressure and clamping force. • The lever lengths shown in parenthesis are the usable length from the edge of the clamp body to the contact bolt. • Tables include maximum operating pressure associated with the arm length shown in the header rows of the table. • The column on the right of the table is the minimum lever length allowed at the associated operating pressure. • Operating the clamp in the non-usable range will damage the clamp and void product warranty.

L1-6063-00 (63mm Bore)

-Non-Usable Range

L = 53 (8)

20.0

L = 72 (27) L = 83 (38)

L = 60 (15)

15.0

L = 100 (55)

10.0

L = 160 (115) L = 140 (95) L = 125 (80)

5.0

0.0

012345678910 Operating Pressure (MPa)

ILML16005-63 REV C

L1-6025-00 (25mm Bore)

3.5

Non-Usable Range

L = 24 (3)

L = 35 (14)

3.0

How to Use the Clamping Force Graphs 1) Start by choosing the lever length you need for your application. 2) Then move along the line and select the clamping force and operating pressure or operating pressure and clamping force needed. Example: Using a L1-6025-00 with a 35 mm lever (14 mm usable length); the clamping force would be 2.0 kN at 6.0 MPa

2.5

L = 40 (19)

L = 46.5 (25.5)

2.0

L = 50 (29)

1.5

L = 61 (40)

1.0

L = 80(59) L = 100(79)

0.5

0.0

6.0

0 1 2 3 4 5

7 8 9 10

ILML16007 REV B

Operating Pressure (MPa)

www.vektek.com

1-800-992-0236

© Vektek February 2021

Made with FlippingBook - professional solution for displaying marketing and sales documents online