Vektek Low Pressure 7MPa Catalog

Palletized Fixture Accessories

Decouplers

Complete 2-Hand Low Pressure Decoupling Solution Automatic Shutoff Valve Decouplers for Single and Double Acting Systems n Decouplers are a complete, self contained package for disconnecting a fixture from its power supply while machining. n Everything is there for you: Quick connect coupling, filters, accumulators, pilot operated check valve and over-pressure relief valve! n Robust pilot operated check valve with 1 to 5 ratio of pilot to check pressure for proven long term reliability. n Internal 25 micron filters for added protection of pilot operated check valve thru ports A1, A2, A3, A4 & C1. Additional filtration provided at port B1. (Filtration for A3, B3 or A4, B4 available by purchasing Vektek filter block L7-0842-05 or L7-0842-06 depending on mounting orientation.) n G1/4 ports and manifold mounting (bottom and rear) connections on all models. n Single acting pallet circuits require 2 hoses to the operating handle for pressure release.

Model No.

L5-6005-40

Pressure Range

3 - 10 MPa

Accumulator Capacity Optional In-Line Filter Cartridge

62 cm³

PLUG "B" PORT FOR S/A SYSTEMS

B3 A3

L7-0048-81

B2 B4

A2 A4

L7-0842-05 (Bottom A4 & B4) or L7-0842-06 (Rear A3 & B3)

Optional Filter Plate (For Manifold Mount Filtration)

B1 C1 A1

I-4

MINIMUM OF 20% CLAMP PRESSURE MUST BE APPLIED TO UNCLAMP

57.5

31.5

SAE 6 PORT. PLUG INSTALLED.

"A1" CLAMP QUICK COUPLER

21.1

28.6

243.8

G1/4

B3

A3

"B1" UNCLAMP QUICK COUPLER

G1/4 PORT ADAPTER. USE IN END PORT IF REQUIRED. (SHIPPED LOOSE)

20.2

117.3

"B1" QUICK CONNECTOR UNCLAMP

28.3

67.1

"A1" QUICK CONNECTOR CLAMP

76.2

105.4

DRILLED FOR M6 SHCS (4X)

ILML56003

REV B

Two - Handed Operating Handle Model No. L5-6005-04 For use with

A4

B4

4.8

54

L5-6005-40 or L5-6005-41

31.8

57.5

Decoupler Model No.

G1/4 MANIFOLD MOUNT

4.8

108

119.4

63.5

Features n Maximum working pressure - 10 MPa n Provides a fast, positive connection to the decoupler. n Ergonomic design reduces operator fatigue. n The Two - Handed Handle may be used with the optional Handle Docking Module to assure the hoses are disconnected from the pallet before it is shuttled into the machine.

15

57.9

27

28.6

88.9

32.9

C1

B1

A1

B2

5.6

SPACER. DISCARD IF BOTTOM MANIFOLD MOUNTED. FOR FILTRATION ADD 11.4 THICK FILTER PLATE.

117.3

4.8

DRILLED FOR M6 SHCS (3X)

G1/4 PORT BOTH ENDS (WITH ADAPTER)

ILML56004

REV B

© Vektek February 2021

1-800-992-0236

www.vektek.com

Made with FlippingBook - professional solution for displaying marketing and sales documents online