Vektek Low Pressure 7MPa Catalog

7 MPa Valves

Pneumatic Confirmation Valve

Pneumatic Confirmation Valve Block Style Model No.

Confirm Clamp Stroke Position Pneumatically The pneumatic confirmation valve confirms the stage of loading before or after clamping. It is adaptable to multiple devices including: swing clamps, link clamps, cylinders and supports. Avoid machine crashes by confirming specific actions before you cycle your machine. It is designed to be used in both coolant and dry environments, and is easily mounted either vertically or horizontally. Confirmation at its finest!  Easily fine tune to your fixture giving you a choice of set and differential pressure.  Confirm signal is based on restricting air flow when tested function is present.  Over-travel sensing will reopen if a device depresses plunger too far on over travel models.  Pneumatic Confirmation Valve can be used with almost any clamping device.  Can help you detect missing or misloaded parts.  Remote venting recommended in coolant applications.

L5-0485-00 L5-0485-01

Over-Travel Sensing

Description

Standard

Max Air Pressure (kPa) Operating Pressure Range (kPa)

1000

1000

70 - 480 70 - 480

Air Flow Rate (L/Min)

10 - 20 10 - 20

@140 kPa Air Pressure @480 kPa Air Pressure

80 Min.

80 Min.

Differential Pressure*

310 Min.

310 Min.

Plunger Stroke (mm)

10 Max

10 Max

Spring (N)

6.6 - 13.3 6.6 - 13.3

Feed Port Nominal Diameter (mm)

Application Setup: Adjust actuator 0.64± 0.5 above valve body with clamp positioned at the bottom of clamping stroke. THIS WILL AVOID VALVE AND ACTUATOR DAMAGE IF CLAMP OVER TRAVELS.

2

2

Manifold and M3

Manifold and M3

Port Types

* Pressure drop when one or more valves open. All valves must be closed for pressure confirmation. Plumb multiple valves in parallel.

NOTE: Mounting hardware not included.

NOTE: MOUNTING HARDWARE NOT INCLUDED E = INPUT A = OUTPUT ( VENT TO ATMOSPHERE ) 1/8 TUBE - M3 CONNECTOR PART NO. P3037020 AVAILABLE TO PURCHASE WITH PNEUMATIC CONFIRMATION VALVE

31.8 22 35.8

J-11

A

2X M3x.5-6H

7 15.9

1.7 STROKE AIR FLOWS BOTH MODELS

E

7.3 STROKE NO AIR FLOWS L5-0485-00

2X 9.5

6.3

M3x.5-6H

8

2X 4.7

50.6

8.5 STROKE NO AIR FLOWS L5-0485-01

2X 1.4

10.2 TOTAL STROKE

1.2 STROKE AIR FLOWS L5-0485-00

For proper sealing, the mating surface must be

5.3

A Port M3 Plug

E Port M3 Plug

flat within 0.08 mm with a maximum surface roughness of 1.6 µm R a

32.9

29.8

ILML504085 REV D

22

4.5

Transi ti on Range

L5-04X5-00 Over Travel Sensing

Air Sensing Control Kit 50-8240-00

ON OFF

Air Pressure Sensor Switch

CLAMPED

Gauge

Valve Stroke 10.16 2.00 8.25

8.90

Air Supply

Swing Clamp Stroke Example

Swing Stroke

Max. 8 Valves

Clamping Stroke

Transi ti on Range

L5-04X5-01 Standard

Air Pressure Regulator Flow Control Valve

ON OFF

 Purchase Vektek Air Sensing Control Kit (Model # 50-8240-00)

CLAMPED

Swing Clamp Stroke Example

Valve Stroke 10.16 2.00

Swing Stroke

ILML504087

REV B

Clamping Stroke

ILML504088 REV B

© Vektek February 2021

1-800-992-0236

www.vektek.com

Made with FlippingBook - professional solution for displaying marketing and sales documents online