7 MPa Valves
Pneumatic Confirmation Valve
Pneumatic Confirmation Valve Block Style Model No.
Confirm Clamp Stroke Position Pneumatically The pneumatic confirmation valve confirms the stage of loading before or after clamping. It is adaptable to multiple devices including: swing clamps, link clamps, cylinders and supports. Avoid machine crashes by confirming specific actions before you cycle your machine. It is designed to be used in both coolant and dry environments, and is easily mounted either vertically or horizontally. Confirmation at its finest! Easily fine tune to your fixture giving you a choice of set and differential pressure. Confirm signal is based on restricting air flow when tested function is present. Over-travel sensing will reopen if a device depresses plunger too far on over travel models. Pneumatic Confirmation Valve can be used with almost any clamping device. Can help you detect missing or misloaded parts. Remote venting recommended in coolant applications.
L5-0485-00 L5-0485-01
Over-Travel Sensing
Description
Standard
Max Air Pressure (bar) Operating Pressure Range (bar)
10
10
0.70 - 4.80 0.70 - 4.80
Air Flow Rate (L/Min)
10 - 20 10 - 20
@1.4 bar Air Pressure @4.8 bar Air Pressure
Min. 0.8 Min. 0.8
Differential Pressure*
Min. 3.1 Min. 3.1
Plunger Stroke (mm)
10 Max
10 Max
Spring (N)
6.6 - 13.3 6.6 - 13.3
Feed Port Nominal Diameter (mm)
2
2
Application Setup: Adjust actuator 0.64± 0.5 above valve body with clamp positioned at the bottom of clamping stroke. THIS WILL AVOID VALVE AND ACTUATOR DAMAGE IF CLAMP OVER TRAVELS.
Manifold and M3
Manifold and M3
Port Types
* Pressure drop when one or more valves open. All valves must be closed for pressure confirmation. Plumb multiple valves in parallel.
NOTE: Mounting hardware not included.
31.8 22 35.8
NOTE: MOUNTING HARDWARE NOT INCLUDED E = INPUT A = OUTPUT (VENT TO ATMOSPHERE)
J-11
A
7 15.9
1.7 STROKE AIR FLOWS BOTH MODELS
E
7.3 STROKE NO AIR FLOWS L5-0485-00
2X 9.5
6.3
M3x.5-6H
8
2X 4.7
50.6
8.5 STROKE NO AIR FLOWS L5-0485-01
2X 1.4
10.2 TOTAL STROKE
1.2 STROKE AIR FLOWS L5-0485-00
5.3
A Port M3 Plug
For proper sealing, the mating surface must be
E Port M3 Plug
32.9
flat within 0.08 mm with a maximum surface roughness of 1.6 µm R a
29.8
M3
ILML504085 REV C
22
4.5
Transion Range
L5-04X5-00 Over Travel Sensing
Air Sensing Control Kit 50-8240-00
ON OFF
Air Pressure Sensor Switch
CLAMPED
Gauge
Valve Stroke 10.16 2.00 8.25
8.90
Air Supply
Swing Clamp Stroke Example
Swing Stroke
Max. 8 Valves
Clamping Stroke
Transion Range
L5-04X5-01 Standard
Air Pressure Regulator Flow Control Valve
ON OFF
CLAMPED
Purchase Vektek Air Sensing Control Kit (Model # 50-8240-00)
Swing Clamp Stroke Example
Valve Stroke 10.16 2.00
Swing Stroke
ILML504087
REV B
Clamping Stroke
ILML504088 REV B
© Vektek January 2019
1-800-992-0236
www.vektek.com
Made with FlippingBook - professional solution for displaying marketing and sales documents online