Quality Control Systems - Metal Cans, Shells and Ends

Z307 Automatic Destructive Gauge

Torus’ Z307 series defines the standard for destructive testing and inspection. The Z307 Automatic Axial Load module determines the maximum axial load force that can be applied prior to container failure, within a short cycle time. The Z308 Dome Growth/Dome Reversal module provides detailed information about the overall change in length of the can when pressure is applied and subsequently removed. The system has programmable internal pressure capability to meet each customer’s exact needs for dome growth. After dome growth, the can sample can be reversed to find the maximum pressure the sample is able to withstand before failure (dome reversal).

Gauge Features: Available for both straight walled and finished beverage cans Industry standard location plattens for component neck support Selectable crush speed Factory set platterns to ensure parallelism between gauge tooling faces

Benefits to your business

> Z307: Multi-size capability with no change tooling for both necked and straight walled can inspection > Z307: Short cycle times > Z307: Customer-specific data outputs (kgf, lbf, newtons etc) > Z307: High-accuracy axial load cell technology > Z308: Multi-size capability with no change tooling for swing line operations > Z308: Customer-specific data outputs (psi, kpa, lbs etc) > Z308: High-accuracy pressure sensor technology

Measurement Features:

Feature

Accuracy

Axial Load

+\- 10N

Dome Growth

+\- 0.10 mm

Also available in Floor-Standing Semi-Automatic

Dome Reversal

+\- 0.05 bar

Technical Specification: Capabilities

ELECTRICITY 100-240 Volts / 50-60 Hz

Typical Range

Can Materials

Aluminium

COMPRESSED AIR 6 bar / 87 PSI

Can Stages

Finished, Straight Walled

Can Finished Height Range

87 - 190 mm

Can Outer Body Diameter

Ø 202 - Ø 307

WEIGHT 650 kg

Internal Neck Diameter

Ø 200 - Ø 209

Click here to view the video

DIMENSIONS (W) 4124mm x (H) 1700mm (L) 1060mm (with 4 lane conveyor)

Axial Load

≤ 2000 N

x

x

Dome Growth/Dome Reversal

≤ 930 kPa

x

35.