21) Explain the key points in a breakout inspection and signs of problems to look out for (Knowledge, intermediate level)

The instructor shall:

Demonstrate the key points in a HV cable breakout inspection, explaining the purpose and importance of every check:

a. correct measurements of breakout (vary up to 2cm)

b.

damage on heat shrink including 4-finger

c.

damage on heat shrink on conductor

d. check that heat shrink doesn’t interfere with T-connector

e.

cuts or pressure marks on the stress cone

f.

cuts or pressure marks on the insulation core

g.

cut marks or damages on bare conductor

h.

z-measurement

i.

mastic tape - purpose and correct application

j.

correct cable lock crimping

Demonstrate different AL/CU connectors and lugs, screw and crimping methods

Illustrate the importance of good contact by sharing stories of issues and consequences from past cases of failures and faults

Facilitate participants in a practical exercise to activate learning, for example:

a. break into teams to recall key points in a breakout inspection

b. award points to the group that recall most key points without reference to notes

The participants shall:

Ask questions about key points in a breakout inspection and signs of problems to look out for.

Engage in the practical exercise and quiz fellow participants on key points in a breakout inspection and signs of problems to look for