High Voltage Standard / V0 - DRAFT 2025-03-21
c.i minimum number of cleats secured as per specific work instruction
Showcase the correct use of HV cable cleats demonstrating and explaining:
a.
types
b.
spacing
c.
fastening techniques as per industry standards.
Facilitate a guided hands-on practice exercise to secure cable with cleating tools
a. Provide participants with HV cables and various cleat types
b. guiding them through the process of fastening cables securely.
The participants shall:
Take part in a cable fastening practical task:
a. practice securing HV cables using the correct cleats and fastening techniques.
b. recommend appropriate fastening solutions, given different environmental conditions
b.i vibration, temperature fluctuations)
ELEMENT 9.2 - INSTALLATION OF THE CABLE LOOP IN TOWER AND WALK DOWN INSPECTION
To achieve the lesson learning objectives, the participants can:
58) Distinguish how to install cable loops in towers (Skills, intermediate level)
59) Perform site cleanup and restore the work area after completing the cable pull (Skills, intermediate level)
The instructor shall:
Installation of the cable loop in tower
a. Illustrate the securing of the cable loop ready for later installation within a tower, emphasising correct handling to avoid mechanical stress
Walk down and inspection of cable after pull