MANUAL OF USE AND MAINTENANCE

28

10. ASSEMBLY INSTRUCTIONS

10.1. Installation measure

Check the compatibility of the carrier fluid (if different from compressed air) with Nylon 6, NBR and Aluminum, referring to the "Compatibility Table" obtainable from the Sicomat. Consider the thermal expansion by activating the most appropriate technical solutions to run the system.

10.2. Preparing the pipe

Use pipe cutter code R230.000.009 - R230.000.010 (depending on the diameter of the tube), position the tool perpendicular to the pipe to be cut and start cutting.

Use chamfering tool (Code R230.000.008 for pipes up to Ø 40, Code R230.000.011 pipes over Ø 40) and chamfering tool for interior (Code R230.000.007) and operate according to the instructions in the literature accompanying the tool in use. Bevel the pipe as evenly as possible without generating chips which are not completely detached from it as these could affect and dama- ge the seal.

Cod. R230.000.008

Cod. R230.000.011

Cod. R230.000.007

Chamfering operation, essential to avoid damaging the seal of the fitting, must follow the indications given in the following scheme.

S

Sm = 1/2 thickness

IMPORTANT: For a perfect link between the pipes, it is recommended that the cut be perfectly perpendicular, remove any burrs and chamfer the edge in order to protect the seal during insertion.

GROOVE

During cutting and chamfering avoid damaging the painted surface of the sealing area (about 50 mm from the end of the tubes).

Made with FlippingBook - professional solution for displaying marketing and sales documents online