KINTEK

RAIMAX - ADJUSTABLE BORING HEAD “PHI” 28-250 MISURAIMAX - MEASURING DEVICE

SUITABLE FOR STANDARD END MILL HOLDERS RAIMAX adjustable head is suitable for boring and reaming machining. All heads are equipped with coolant nozzle. Tool cutting diameter is adjusted by turning a screw. Adjustment screw acts on the insert carrier, that slides within a U-shaped groove obtained in tool body. For centesimal adjustment of cutting diameter, MISURAIMAX device, consisting of a tube and a centesimal or millesimal dial gauge, can be used.

13

12

RAIMAX ® Head

INSERT CARRIERS

14

Ø

SHANK

1

SCGCL

9

4 4

STGPL

11

15

SSXCL

10

7

6

1

1. RAIMAX tool body 2. Insert carrier adjustment screw

9. Coolant nozzle 10. MISURAIMAX locking screw 11. Measuring device arm 12. Dial gauge locking screw 13. Dial gauge 14. Gauge probe 15. Tube

WITHOUT COVER

3

5

8

3. Cone locking screw 4. Short cover screw 5. Cover screws 6. Cover 7. Insert carrier 8. Spring

6

2

5 RAIMAX INSTRUCTIONS: 1. Unscrew the three screws (5) and remove the cover (6) 2. Loosen the two screws (4) 3. Remove the cartridge (7) from the slot 4. Fix the head on the holder and clamp it with the screw (3) 5. Put again the cartridge (7) in the slot. 6. Tighten the screws (5) to assembly the cover 7. Adjust the measure of cutting diameter rotating the screw. This will cause the shifting of the cartridge. 8. Tighten the two screws (4) 9. RAIMAX boring head is ready to be used 5

COD.

SCREW

COVER

SCREW FOR COVER

SCREW

SCREW

RAIMAX 30 RAIMAX 40 RAIMAX 50 RAIMAX 75 RAIMAX 100 RAIMAX 150

KSR M8 R/L KSR M8x20 KSR M10x20 KSR M12x25 KSR M20X KSR M20X

KCC30 KCC40 KCC50 KCC75 KCC100 KCC150

2 x KVCC30 3 x KVCC40 3 x KVCC50 4 x KVCC75 4 x KVCC100 4 x KVCC150

KVR30 KVR40 KVR50 KVR75 KVR100 KVR150

2 x KGG30 2 x KGG40 2 x KGG50 2 x KGG75 2 x KGG100 2 x KGG150

MISURAIMAX INSTRUCTIONS: 1. Check the two locking screws of the cartridge (4). These must be tightened. 2. Fix MISURAIMAX without dial gauge up to the head and tighten the screw (10). 3. Insert the dial gauge in the holding bar, push it up to the head till the contact point will touch the edge of insert of cartridge. Then tighten carefully the locking screw of the dial gauge (12). 4. Zerofill the dial gauge 5. Loosen the two locking screws of the gauge (4) 6. Modify the boring diameter of the head rotating the adjustment screws (2). 7. Check also the centesimal variation on the gauge display. After getting the measure, tighten the screws (4) 8. Remove MISUIRAMAX loosening the screws (10) 9. RAIMAX is now ready to be used

COD.

MISURAIMAX 30-40 + Dial indicator 1/100 0-5 mm MISURAIMAX 30-40 + Dial indicator 1/100 0-5 mm MISURAIMAX 50 + Dial indicator 1/100 0-10 mm MISURAIMAX 75 + Dial indicator 1/100 0-10 mm MISURAIMAX 100 + Dial indicator 1/100 0-10 mm MISURAIMAX 150 + Dial indicator 1/100 0-10 mm

ADJUSTABLE BORING HEADS

226

Made with FlippingBook - Online Brochure Maker