PLANT ENGINEERING
FLOW MONITOR JSW WITH DEVICE PLUG
ILLUSTRATIONS
JSW
JSW
JSW
The device works according to the principle of a spring-loaded paddle with magnetic control of a micro-switch. When in rest position or if the switch-off value is undershot (= ‘dropping switching point’), contacts 2 and 3 are closed and can be used as signal contacts. Upon reaching the upper switching value (= switch-on value or ‘switching point ris - ing’), the contact changes and 2 to 1 are closed. If used as a water shortage safeguard, for example, a pump can be switched on with these contacts. The actual flow quantity must in any case be higher than the switch-on value, but there is no upper limit. The switching points given in the table apply to flow monitors with an attached T-piece and a water temperature of 20 °C in a horizontal pipe. The devices are set to the mini - mum switch-off value at the factory, but can be adapted to an existing plant. To that end, the cover of the setting screw on the front side, which is designed so that it cannot be lost, is pushed up in the direction of the arrow and the setting screw is rotated by a maximum of 7 revolutions in the plus direction. With a switching value range of, for example, 13–16.5 l / min, a setting range of 3.5 l / min is obtained. With a total of seven permissible screw revolutions, this gives a change of 0.5 l / min per screw revolution.
207
Catalogue 2024
Prices valid from 01.01.2024 - 31.12.2024, prices may be subject to change | V1