BUILDING AUTOMATION
BACNET ROOM CONTROLLER KTRBUU FLUSH-MOUNTED INSTALLATION – DESIGN BERLIN FLUSH-MOUNTED
TECHNICAL DATA
APPLICATION
Design:
Berlin flush-mounted PC, PMMA, ABS plastic
The alre BACnet individual room controller with graphic display was specially developed for time-dependent heating and cooling operation in 2 or 4-pipe systems. The controller can be used in a wide range of applications, such as hotels, residential, office and business premises as well as hospitals and schools. The communication takes place via BACnet according to DIN EN ISO 16484- 5 with the BACnet MS / TP network protocol. The room controller is therefore compatible with all common building automation systems. The controller corresponds to the BACnet profile ‘B-AAC’ (BACnet Advanced Application Controller). The predefined applications cover a wide range of applications for room tempera- ture control in room automation. Special colours such as anthracite and aluminium are available depending on the project.
Housing material: Operating voltage: Ambient temperature: Storage temperature: Permissible atmospheric humidity: Electrical connection:
230 V AC, 50 Hz
0 to 40 °C
−20 to +70 °C
max. 95% rel. humidity, non-condensing pluggable screw terminals Mains voltage side
0.75 – 2.5 mm² low voltage side 0.08 – 1.5 mm²
Mounting / attachment:
In flush-mounted socket – can be adapted to fit virtually any switch range (deep flush-mounted socket recommended) see adaptation list on page 50
Protection rating: Protection class: Safety and EMC:
IP30
II
according to DIN EN 60730
Max. switching voltage: Min. switching voltage:
230 V AC, 50 Hz 230 V AC, 50 Hz
Switching power:
690 W
Max. power consumption: Max. switching current:
approx. 1 W (2.2 VA)
per 3 (0.5) A (max. 5 valve actuators per output)
Switching element: Switching contact:
2 relays
2 NO contacts
Output signal:
Switching heating, cooling, heating / cooling, analogue 0 – 10 V (5 mA) to control a speed-controlled fan internal NTC, optional external ‘Sensor 2’ * (NTC 47k), dew point sensor
Sensor:
Control range: Setting range:
5 to 40 °C
standard setting range for heating (5 to 30 °C), second setting range for cooling (18 to 40 °C)
Hysteresis: Display type:
< 1 K
illuminated graphical display
Pipe system compatibility:
2-pipe and 4-pipe
TYPE / IMAGE
ITEM NO.
FEATURES
CIRCUIT DIAGRAM
EURO / PG
KTRBUu217.456#21
Surface finish: glossy Housing colour: pure white, similar to RAL 9010 Scope of delivery: controller, 50 x 50 mm cover, pure white (similar to RAL 9010), glossy, alre frame ‘Berlin’
UA230000
454.50 / IV
L N
230V~ 50Hz
SELV
max. 5mA
O3
N
0—10V
D− D+ I1
L
RS485
O2 O1
NTC TPS
3(0,5)A
* Depending on the selected system scheme, a menu setting can be used to select whether control should be based on the internal or external sensor. In the intermediate positions, if both sensors are used, a weighting is applied to the internal room sensor and the external temperature sensor. The weighting allows for compensation of different structural conditions such as large window areas or cardinal directions. For very slow controlled systems, it is recommended to assign a higher weighting to the temperature sensor than to the internal room sensor.
45
Catalogue 2023
Prices valid from 01.01.2024 - 31.12.2024, prices may be subject to change | V1
Made with FlippingBook Annual report maker