TIE-ROD CYLINDERS - 2500 PSI
OUTSIDE DIAMETER ROD THREAD A 2
PORT SIZE
MODEL CODE CYLINDER BORE TR2.5-20XX-S 2.00 TR2.5-25XX-S 2.50 TR2.5-30XX-S 3.00 TR2.5-35XX-S 3.50 TR2.5-40XX-S 4.00
B C 3
D 4
E 5
F G H I
J 4
2.38 2.89 3.39 3.87 4.50
1 1/8-12 UNF 10.25 2.00 1.01 2.00 4.17 2.44 1.14 2.00 2.12 2.50 SAE-08 1 1/8-12 UNF 10.25 2.00 1.01 2.00 4.17 2.44 1.14 2.00 2.12 2.50 SAE-08 1 1/4-12 UNF 10.25 2.00 1.01 2.00 4.14 2.72 1.14 2.00 2.12 2.72 SAE-08 1 1/4-12 UNF 10.25 2.00 1.01 2.00 4.09 2.72 1.14 2.00 2.12 2.72 SAE-08 1 1/4-12 UNF 10.25 2.00 1.01 2.00 3.82 2.72 1.14 2.12 2.12 2.72 SAE-08
1 . FOR TR2.5-2518 TO TR2.5-2536: ROD THREAD= 1.250-12 UNF 2 . FOR 8.00" ASAE STROKE: A= 12.25" FOR 16.00" ASAE STROKE: A= 15.50" 3 . FOR 16.00" ASAE STROKE: C= 1.26" 4 . FOR TR2.5-4016-ASAE TO TR2.5-4036: D= 2.50" J=2.75" ROD THREAD= 1.500-12 UNF 5 . FOR 8.00" ASAE STROKE: E= 5.75" (2.00" TO 3.00" BORE) E=5.62" (3.50" BORE) E=5.56’’ (4.00" BORE) FOR 16.00" ASAE STROKE: E= 9.00" (2.00" TO 3.00" BORE) E=8.87" (3.50" BORE) E=8.81’’ (4.00" BORE)
MAXIMUM RETRACTED WORKING PRESSURE= 2500 psi MAXIMUM EXTENDED WORKING PRESSURE= SEE TABLE FOR ALL CYLINDER, RETRACTED TOLERANCE ± 1/8’’
DIMENSIONS
ROD DIAMETER PIN SIZE
PORT SIZE
COLUMN LOADS (LBS)
PRESSURE (PSI)
WEIGHT (LBS)
MODEL CODE BORE X STROKE
RETRACTED EXTENDED
TR2.5-2004-S TR2.5-2006-S TR2.5-2008-S
2” X 4” 2” X 6” 2” X 8” 2” X 8” 2” X 10” 2” X 12” 2” X 14” 2” X 16” 2” X 18” 2” X 20” 2” X 24” 2” X 30” 2” X 36” 2″ X 40” 2″ X 48”
14 1/4” 16 1/4” 18 1/4” 20 1/4” 20 1/4” 22 1/4” 24 1/4” 26 1/4” 28 1/4” 30 1/4” 34 1/4” 40 1/4” 46 1/4” 50 1/4” 58 1/4”
18 1/4” 22 1/4” 26 1/4” 28 1/4” 30 1/4” 34 1/4” 38 1/4” 42 1/4” 46 1/4” 50 1/4” 58 1/4” 70 1/4” 82 1/4” 90 1/4” 106 1/4”
7800 7800 7800 7800 7800 7800 7800 7800 7000 5900 4400 3000 2200 1700 1300
2500 2500 2500 2500 2500 2500 2500 2500 2200 1900 1400
16 17 19 20 20 22 24 25 27 28 31 36 41 44 49
TR2.5-2008-ASAE-S*
TR2.5-2010-S TR2.5-2012-S TR2.5-2014-S TR2.5-2016-S TR2.5-2018-S TR2.5-2020-S TR2.5-2024-S TR2.5-2030-S TR2.5-2036-S TR2.5-2040-S TR2.5-2048-S
SAE-08
1-1/8”
1”
900 700 500 400
COLUMN LOAD IS THE MAXIMUM PUSHING LOAD SUGGESTED USING A MINIMUM SAFETY FACTOR OF 2 AND BASED ON A PIN TO PIN MOUNTING CALCULATION. * ASAE = AMERICAN SOCIETY OF AGRICULTURE ENGINEERS DESIGNATES AN INDUSTRY MOUNTING STANDARD FOR 8” AND 16” STROKE CYLINDERS
HYDRO CUSTOM IS NOT RESPONSIBLE FOR INCORRECT RESULTS OBTAINED WITH FIGURES IN THIS DOCUMENT. INFORMATION IS FOR REFERENCE ONLY. NO OTHER CONDITIONS ARE EXPRESSED OR IMPLIED.
PAGE 21